• Counter Flow and Cross Flow Cooling Tower for Data Center
  • Counter Flow and Cross Flow Cooling Tower for Data Center
  • Counter Flow and Cross Flow Cooling Tower for Data Center
  • Counter Flow and Cross Flow Cooling Tower for Data Center
  • Counter Flow and Cross Flow Cooling Tower for Data Center
  • Counter Flow and Cross Flow Cooling Tower for Data Center

Counter Flow and Cross Flow Cooling Tower for Data Center

After-sales Service: on-Site Installation
Warranty: 2 Years
Cooling Method: Counter Flow/Cross Flow/Combined Flow
Ventilation Mode: Mixing Ventilation
Material: Metal
Air Contact Form: Wet and Dry
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Overview
  • Product Description
  • Working Principles
  • Product Parameters
  • Detailed Photos
  • Production Process
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE
Condition
New
Product
Closed Combined Flow Evaporative Condenser
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/ABB/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Advantage
Water Saving
Structure
Compact
Application
Food Industry and Chemical Medicine
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Product Description

Product Description

Counterflow and crossflow are the two primary types of cooling tower configurations, while combined flow cooling towers are a variation that combines elements of both. Here's a breakdown of the differences:

1. Counterflow Cooling Tower:
   - In a counterflow cooling tower, air flows vertically upwards while water flows vertically downwards.
   - The water enters the tower from the top and flows over the fill material while the air is drawn in from the bottom, passing through the fill material in the opposite direction of the water flow.
   - Counterflow towers generally have better thermal performance and require less fan power compared to crossflow towers.

2. Crossflow Cooling Tower:
   - In a crossflow cooling tower, air flows horizontally across the fill material while water flows vertically downwards.
   - Water is distributed over the fill material at the top of the tower and is then cooled as it flows down through the fill, while air is drawn through the tower perpendicular to the water flow.
   - Crossflow towers are typically larger and less efficient than counterflow towers due to the air and water flow directions.

3. Combined Flow Cooling Tower:
   - Combined flow cooling towers combine elements of both counterflow and crossflow designs.
   - In a combined flow tower, the water flow is mainly counterflow, while the air flow is partly crossflow.
   - These towers aim to achieve a balance between the advantages of both counterflow and crossflow designs, offering improved efficiency and performance over traditional crossflow towers but not as high as counterflow towers.

In summary, the main difference between counterflow and combined flow cooling towers lies in the direction of airflow, with combined flow towers incorporating features of both counterflow and crossflow designs to optimize performance.

 

Closed Circuit cooling tower
Combined Flow Cooling Tower
Counter Flow and Cross Flow Cooling Tower for Data Center
Counter Flow Cooling Tower
Counter Flow and Cross Flow Cooling Tower for Data Center
Working Principles

 

Working PrincipleCounter Flow and Cross Flow Cooling Tower for Data Center


 

Product Parameters

Technical Database

Combined Flow Cooling Tower
MODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BHX-30 30 1 3 135000 1 1.1 36 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 45 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.1 45 1925 2350 4220
BHX-60 60 1 5.5 75000 1 1.5 65 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 65 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 84 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 84 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 84 3770 2200 4965
BHX-110 110 3 3 40000 1 3 120 4240 2200 4720
BHX-125 125 3 4 45000 1 3 120 4240 2200 4965
BHX-135 135 4 3 45000 1 3 120 5610 2200 4220
BHX-150 150 4 3 40000 1 3 120 5610 2200 4730
BHX-165 165 4 4 45000 1 3 120 5610 2200 4965
BHX-183 183 4 4 5000 1 4 170 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 230 7450 2200 4730
BHX-226 226 4 4 45000 1 5.5 230 7450 2200 4965
BHX-250 250 5 4 45000 1 5.5 230 9300 2200 4720
BHX-265 265 5 4 45000 1 5.5 230 9300 2200 4965
BHX-280 280 6 4 45000 1 5.5 230 9300 2200 4965
Counter Flow Cooling Tower
ODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BNX-10 12 1 1.5 18000 1 0.55 23 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 1925 1840 3840
BNX-40 42 1 4 60000 1 1.1 45 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 2470 1840 4450
BNX-70 70 1 7.5 10000 1 2.2 84 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 3770 1840 4220
BNX-110 110 2 5.5 75000 1 3 120 3770 2200 4450
BNX-125 125 2 5.5 75000 1 3 120 3770 2200 4350
BNX-135 135 2 5.5 87000 1 4 170 4846 2200 4650
BNX-150 150 2 7.5 100000 1 4 170 4846 2200 4350
BNX-165 165 3 4 65000 1 4 170 5610 2200 4650
BNX-180 183 3 5.5 75000 1 4 170 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 9030 2200 4965
 
Detailed Photos

 

Product Details
Combined Flow Cooling Tower
Counter Flow and Cross Flow Cooling Tower for Data CenterCounter Flow Cooling Tower
 Counter Flow and Cross Flow Cooling Tower for Data Center          
Production Process

Production Process

Counter Flow and Cross Flow Cooling Tower for Data Center
Certifications

Counter Flow and Cross Flow Cooling Tower for Data Center
Packaging & Shipping

Shipment Procedures
Counter Flow and Cross Flow Cooling Tower for Data Center
Projects

Counter Flow and Cross Flow Cooling Tower for Data Center
Customer Visiting and Exhibition
Counter Flow and Cross Flow Cooling Tower for Data CenterCounter Flow and Cross Flow Cooling Tower for Data Center
Cooperated Partner
Counter Flow and Cross Flow Cooling Tower for Data Center
FAQ

 

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
50
Year of Establishment
2012-01-13