High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower

Product Details
Customization: Available
After-sales Service: on-Site Installation
Warranty: 2 Years
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
  • High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Cooling Method
Counter Flow
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Product
Closed Counter Flow Cooling Tower
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/a Bb/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Shape
Round/Bottle
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Product Description

 
Product Description

Closed type counter flow cooling tower


High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Working Principle
High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Advantages

1-No infill designed, more compact structure, lower profile, less installation area required,and easy for transport and installation.
2-Suitable to severe environment as its structure much more close, which couldvprevent from sand and dust. So it widely used for casting workshop,mining factory etc.
3-Suitable to high temperature fluid, because hot spraying water will not distort pvC fill as no pvC fill designed.
4-Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.

Notes of selecting a cooling tower as below:

1. The structure materials of cooling tower should be stable, durable, corrosion-resistant, and its assembly should be precise.

2. In the cooling tower,  it should be uniform water distribution, small fluid flow on the wall, the reasonably selected splash device, and it should not be easily blocked.

3. The type of cooling tower water filling should meet the requirements of water quality and water temperature.

4. The fan is should be long-term normal operation without vibration and abnormal noise, and the blades have good water erosion resistance and sufficient strength. The installation angle of the fan blades is adjustable, but the angle must be consistent, and the current of the motor does not exceed the rated current of the motor.

5. Low power consumption and low cost, small and medium-sized steel frame glass cooling towers also require light weight.

6. Cooling towers should be installed away near heat sources, exhaust gas and flue gas generation points, chemical storage areas and coal piles.

7. About the distance between cooling towers, between towers and other buildings, in addition to considering the ventilation requirements between the towers and the mutual influence between towers and buildings, we should also consider the safety distance of building fire prevention and explosion prevention, the construction and maintenance requirements of cooling towers.

8. The water inlet pipe direction of the cooling tower can be rotated at 90°, 180°and 270°.

9. The material of the cooling tower can withstand low temperatures of -50 ºC, but for areas where the average temperature of the coldest month is below -10ºC, it should be stated when ordering so that anti-icing measures can be taken. The cost of the cooling tower increases by about 3%.

10. The turbidity of the circulating water is not more than 50mg/l, and not more than 100mg/l in the short term. It should not contain oil and mechanical impurities. Algae removal and water quality stabilization measures should be taken when necessary.

11. The water distribution system is designed according to the nominal water volume. If the actual water volume differs from the nominal water volume by more than ±15%, it should be stated when ordering so that the design can be modified.

12. During the storage and transportation of cooling tower parts, heavy objects shall not be placed on them, they shall not be exposed to the sun, and attention shall be paid to fire prevention. During the installation, transportation and maintenance of cooling towers, open flames such as electric and gas welding shall not be used, and firecrackers and fireworks shall not be set off nearby.

13. For the design of multiple round towers, the net distance between towers should be maintained at no less than 0.5 times the diameter of the tower body. Cross flow towers and counter flow square towers can be arranged in parallel.

14. The water pump should be matched with the cooling tower capacity to meet the process requirements such as flow rate and head.

15. When selecting multiple cooling towers, try to choose the same model.



 
Product Parameters

 

Technical Database

High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
 
MODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BHX-30 30 1 3 135000 1 1.1 36 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 45 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.1 45 1925 2350 4220
BHX-60 60 1 5.5 75000 1 1.5 65 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 65 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 84 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 84 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 84 3770 2200 4965
BHX-110 110 3 3 40000 1 3 120 4240 2200 4720
BHX-125 125 3 4 45000 1 3 120 4240 2200 4965
BHX-135 135 4 3 45000 1 3 120 5610 2200 4220
BHX-150 150 4 3 40000 1 3 120 5610 2200 4730
BHX-165 165 4 4 45000 1 3 120 5610 2200 4965
BHX-183 183 4 4 5000 1 4 170 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 230 7450 2200 4730
BHX-226 226 4 4 45000 1 5.5 230 7450 2200 4965
BHX-250 250 5 4 45000 1 5.5 230 9300 2200 4720
BHX-265 265 5 4 45000 1 5.5 230 9300 2200 4965
BHX-280 280 6 4 45000 1 5.5 230 9300 2200 4965

Product Details
High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
   High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower                                           High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
The counter flow cooling tower has 4 main parts to support its operation.
They are Fan&Motor,Spray Pump,and Hear exchanger coil as the pocture shows.
 
Company Profile

 

Who We Are

High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Shipment Procudures

High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Customer Visiting and Exhibition

High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling TowerHigh Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
Cooperated Partner

High Quality Low Noise Water Cooling Tower Steel Closed Circular Cooling Tower
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now