Product Description
Closed type counter flow cooling tower
Working Principle
Detailed selection of cooling tower:
1. First, the inlet water temperature of the cooling tower should be clear, then to select a standard cooling tower, a medium-temperature cooling tower or a high-temperature cooling tower.
2. Second, noise requirements, based on the applied equipment or on-site situation you can choose a cross-flow cooling tower or a counter-flow cooling tower.
3. Thirdly, considering the chiller, we must know the cooling water volume of the chiller. Generally speaking, the cooling tower flow rate should be greater than the cooling water volume of the chiller. (Generally 1.2-1.25 times).
4. Finally, when multiple units are connected in parallel, try to choose the same model cooling tower.
Advantages
1-No infill designed, more compact structure, lower profile, less installation area required,and easy for transport and installation.
2-Suitable to severe environment as its structure much more close, which couldvprevent from sand and dust. So it widely used for casting workshop,mining factory etc.
3-Suitable to high temperature fluid, because hot spraying water will not distort pvC fill as no pvC fill designed.
4-Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.
Technical Database
Combined Flow Cooling Tower |
|
|
|
|
|
|
|
|
MODEL |
CAPACITY
(kW) |
FAN |
PUMP |
DIMENSION (mm) |
QTY |
POWER (kW) |
AIR VOLUM PER SET (m3/h) |
QTY |
POWER (kW) |
WATER VOLUME PER SET(m3/h) |
Lenth |
Width |
Height |
BHX-30 |
30 |
1 |
3 |
135000 |
1 |
1.1 |
36 |
1925 |
2380 |
4220 |
BHX-40 |
40 |
1 |
4 |
45000 |
1 |
1.1 |
45 |
1925 |
2380 |
4220 |
BHX-50 |
50 |
1 |
5.5 |
65000 |
1 |
1.1 |
45 |
1925 |
2350 |
4220 |
BHX-60 |
60 |
1 |
5.5 |
75000 |
1 |
1.5 |
65 |
1925 |
2900 |
4220 |
BHX-70 |
70 |
1 |
7.5 |
87000 |
1 |
1.5 |
65 |
1925 |
2900 |
4965 |
BHX-80 |
80 |
2 |
4 |
45000 |
1 |
2.2 |
84 |
3770 |
2200 |
4220 |
BHX-90 |
90 |
2 |
4 |
45000 |
1 |
2.2 |
84 |
3770 |
2200 |
4720 |
BHX-100 |
100 |
2 |
4 |
45000 |
1 |
2.2 |
84 |
3770 |
2200 |
4965 |
BHX-110 |
110 |
3 |
3 |
40000 |
1 |
3 |
120 |
4240 |
2200 |
4720 |
BHX-125 |
125 |
3 |
4 |
45000 |
1 |
3 |
120 |
4240 |
2200 |
4965 |
BHX-135 |
135 |
4 |
3 |
45000 |
1 |
3 |
120 |
5610 |
2200 |
4220 |
BHX-150 |
150 |
4 |
3 |
40000 |
1 |
3 |
120 |
5610 |
2200 |
4730 |
BHX-165 |
165 |
4 |
4 |
45000 |
1 |
3 |
120 |
5610 |
2200 |
4965 |
BHX-183 |
183 |
4 |
4 |
5000 |
1 |
4 |
170 |
7450 |
2200 |
4220 |
BHX-200 |
200 |
4 |
4 |
45000 |
1 |
5.5 |
230 |
7450 |
2200 |
4730 |
BHX-226 |
226 |
4 |
4 |
45000 |
1 |
5.5 |
230 |
7450 |
2200 |
4965 |
BHX-250 |
250 |
5 |
4 |
45000 |
1 |
5.5 |
230 |
9300 |
2200 |
4720 |
BHX-265 |
265 |
5 |
4 |
45000 |
1 |
5.5 |
230 |
9300 |
2200 |
4965 |
BHX-280 |
280 |
6 |
4 |
45000 |
1 |
5.5 |
230 |
9300 |
2200 |
4965 |
Couner Flow Cooling Tower |
|
|
|
|
|
|
|
|
|
MODEL |
CAPACITY
(kW) |
FAN |
PUMP |
DIMENSION (mm) |
QTY |
POWER (kW) |
AIR VOLUM PER SET (m3/h) |
QTY |
POWER (kW) |
WATER VOLUME PER SET(m3/h) |
Lenth |
Width |
Height |
BNX-07 |
8 |
1 |
0.75 |
15000 |
1 |
0.37 |
16 |
1230 |
1150 |
3180 |
BNX-10 |
12 |
1 |
1.5 |
18000 |
1 |
0.55 |
23 |
1230 |
1150 |
3440 |
BNX-20 |
21 |
1 |
2.2 |
30000 |
1 |
0.75 |
28 |
1925 |
1150 |
3650 |
BNX-30 |
33 |
1 |
3 |
45000 |
1 |
1.1 |
53 |
1925 |
1840 |
3840 |
BNX-40 |
43 |
1 |
4 |
60000 |
1 |
1.1 |
53 |
1925 |
1840 |
4220 |
BNX-50 |
51 |
1 |
5.5 |
75000 |
1 |
1.5 |
70 |
2470 |
1840 |
4220 |
BNX-60 |
61 |
1 |
7.5 |
87000 |
1 |
1.5 |
70 |
2470 |
1840 |
4450 |
BNX-70 |
70 |
1 |
7.5 |
100000 |
1 |
2.2 |
84 |
2790 |
1840 |
4450 |
BNX-80 |
80 |
2 |
4 |
65000 |
1 |
2.2 |
100 |
3770 |
1840 |
4020 |
BNX-90 |
90 |
2 |
4 |
65000 |
1 |
2.2 |
100 |
3770 |
1840 |
4220 |
BNX-100 |
100 |
2 |
4 |
65000 |
1 |
2.2 |
100 |
3770 |
1840 |
4450 |
BNX-110 |
110 |
2 |
5.5 |
75000 |
1 |
3 |
120 |
3770 |
2200 |
4220 |
BNX-125 |
125 |
2 |
5.5 |
75000 |
1 |
3 |
120 |
3770 |
2200 |
4450 |
BNX-135 |
135 |
2 |
5.5 |
87000 |
1 |
4 |
180 |
4846 |
2200 |
4350 |
BNX-150 |
150 |
2 |
7.5 |
100000 |
1 |
4 |
180 |
4846 |
2200 |
4650 |
BNX-165 |
165 |
3 |
4 |
65000 |
1 |
5.5 |
230 |
5610 |
2200 |
4350 |
BNX-180 |
183 |
3 |
5.5 |
75000 |
1 |
5.5 |
230 |
5610 |
2200 |
4650 |
BNX-200 |
200 |
3 |
5.5 |
80000 |
1 |
5.5 |
230 |
5610 |
2200 |
4680 |
BNX-225 |
225 |
3 |
7.5 |
87000 |
2 |
3 |
120 |
6510 |
2200 |
4650 |
BNX-250 |
250 |
4 |
5.5 |
75000 |
2 |
3 |
120 |
7230 |
2200 |
4650 |
BNX-265 |
265 |
4 |
5.5 |
75000 |
2 |
3 |
120 |
7450 |
2200 |
4650 |
BNX-280 |
280 |
4 |
5.5 |
75000 |
2 |
3 |
150 |
8050 |
2200 |
4965 |
BNX-300 |
300 |
4 |
7.5 |
87000 |
2 |
4 |
180 |
8640 |
2200 |
4965 |
Product Details
The counter flow cooling tower has 4 main parts to support its operation.
They are Fan&Motor,Spray Pump,and Hear exchanger coil as the pocture shows.
Company Profile
Who We Are
Shipment Procudures
Customer Visiting and Exhibition
Cooperated Partner
FAQ
1 Q: Is your company a manufacture or a trading company?
A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975.
The famous brand-"Heng An" is well known not only China but all over the world.
As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.
2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?
A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
At same situation, counter flow tower are inherently more efficient than cross flow tower.
3 Q: How do you get repair parts and how long does it take?
A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.
4 Q: What if you don't have the professional engineers to install or maintain the tower?
A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince.
5 Q: How can I choose a suitable cooling tower?
A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.
Application |
Which industry or system using for? For example, HAVC system, casting cooling system |
Water flow capacity |
How many tons of water treatment per hour? |
Inlet water temp. |
Tempreture of hot water to be cooled |
Outlet water temp. |
Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture. |
Wet bulb temp. |
Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers. |
Power supply |
The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer. |