PVC Fills for Cross Flow Type Cooling Tower

Product Details
Customization: Available
After-sales Service: Video Technical Support,Field Maintenance Repair
Cooling Method: Counter Flow
Still deciding? Get samples of US$ 1/piect
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • PVC Fills for Cross Flow Type Cooling Tower
  • PVC Fills for Cross Flow Type Cooling Tower
  • PVC Fills for Cross Flow Type Cooling Tower
  • PVC Fills for Cross Flow Type Cooling Tower
  • PVC Fills for Cross Flow Type Cooling Tower
  • PVC Fills for Cross Flow Type Cooling Tower
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Ventilation Mode
Natural Ventilation
Material
PVC
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Insulation
IP55,Insulation Class F
Water Loss Rate
Less Than 0.002%
OEM
Accept
PVC Type
Bac/Spx/Marley/Liangchi/Brentwood
Transport Package
Oversea Ship Standard
Trademark
HACST
Origin
China
HS Code
3904109001
Production Capacity
500000piece /Year

Packaging & Delivery

Package Size
2500.00cm * 1200.00cm * 0.19cm
Package Gross Weight
0.100kg
Lead Time
4 days (1 - 500 piece)
To be negotiated ( > 500 piece)

Product Description

PP PVC Filler for cross flow BAC, EVAPCO, SPINDLE Cooling Tower
 

Product Description

PVC Fills for Cross Flow Type Cooling Tower

PVC Fills for Cross Flow Type Cooling Tower

 

PVC Fills for Cross Flow Type Cooling Tower
 
 
PVC Fills for Cross Flow Type Cooling Tower
 
PVC Fills for Cross Flow Type Cooling Tower
 
 
Name cooling tower fill
Material PVC, PP
Width 610mm, 720mm,813mm,915mm,1020mm,1120mm,1220mm,1320mm,1420mm,1520mm
Regular Length 1854mm.2060mm,2450mm,2678mm,2980mm,3090mm or customer request
Thickness 0.25-0.5mm
Common Dimension 1220mm*2980mm*0.38mm
Color black,gray
Fluted size 19mm
Temperature 60ºC-35ºC
Packing Details In bundle, wooden pallet or as requested
Free Sample Delivery Time 5-10dyas
Production Date Within 30days
Cross flow type honeycomb PVC infill,special designed with distinctive big surface area air channel where
spraying water flow as a big water film and enlarge water flow time inside of infill,to extend the water cooling
effect ,and have advantages of small drag coefficient,anti-aging ,no easy to deformation.
 

PVC Fills for Cross Flow Type Cooling Tower

 

Company Profile

PVC Fills for Cross Flow Type Cooling Tower

 

PVC Fills for Cross Flow Type Cooling Tower

 

FAQ


1.Q: Your company is a manufacture or trading company?
A: We are  leading cooling towerand evaporative condenser manufacturer since the year of 1975 with the "famous brand"-Heng An manufacture in China.

2.Q: How do I get repair parts and how long does it take?
A: We have workshop can supply all parts of the product, and 90% of spare parts can be distributed to any 
place in the world within one week!

3.Q: What if I don't have the professional engineer to install or maintain the product?
A: We could send experience engineers on site to install the product and train your staff for equipment 
operation and maintenance.

4.Q: How can I choose a suitable model?
A: As long as you provide the following information, we can assist to design and select the model for you.

Application:

(Explanations: Where the cooling towers will be used for?

 e.g. for HAVC system, Air Compressors, Melting Furnaces, etc.)

Water Flow Rate: (Explanations: How many Tons of water required per hour?)
Inlet Water Temp.: (Explanations: Temperature of hot water to be cooled)
Outlet Water Temp.:

(Explanations: Temperature of cooled water, 

usually it shall be at least 3~4 °C higher than the wet-bulb temp.) 

 Wet-bulb Temp.: (Explanations: Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers)
Power Supply:

(Explanations: 380V/3 Phases is standard, which we could have

 in stock, but for customized towers, the delivery time could be longer)




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier