MODEL |
CAPACITY (M3/h) |
FAN |
WATER SPRAYING PUMP |
INLET/OUTLET DN(MM) |
WEIGHT |
DIMENSION |
|||||||
QTY |
POWER(K/W) |
AIR VOLUME PER SET (M3/h) |
QTY |
POWER (K/W) |
WATER VOLUME PER SET (M3/h) |
SHIPPING (KG) |
OPERATIONG (KG) |
LENGTH (MM) |
WIDTH (MM) |
HEIGHT (MM) |
|||
| BHX-30 | 30 | 1 | 3 | 35000 | 1 | 1.1 | 53 | DN80 | 2390 | 3790 | 1925 | 2380 | 4220 |
| BHX-40 | 40 | 1 | 4 | 45000 | 1 | 1.1 | 53 | DN100 | 2510 | 3910 | 1925 | 2380 | 4220 |
| BHX-50 | 50 | 1 | 5.5 | 65000 | 1 | 1.5 | 70 | DN100 | 2760 | 4340 | 1925 | 2580 | 4220 |
| BHX-60 | 60 | 1 | 5.5 | 75000 | 1 | 1.5 | 70 | DN100 | 3290 | 5140 | 1925 | 2900 | 4220 |
| BHX-70 | 70 | 1 | 7.5 | 87000 | 1 | 1.5 | 70 | DN100 | 3680 | 5530 | 1925 | 2900 | 4965 |
| BHX-80 | 80 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN100 | 4230 | 7650 | 3770 | 2200 | 4220 |
| BHX-90 | 90 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN125 | 4510 | 7930 | 3770 | 2200 | 4720 |
| BHX-100 | 100 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN125 | 4620 | 8040 | 3770 | 2200 | 4965 |
| BHX-110 | 110 | 3 | 3 | 40000 | 1 | 3 | 150 | DN125 | 6170 | 10170 | 4240 | 2200 | 4720 |
| BHX-125 | 125 | 3 | 4 | 45000 | 1 | 3 | 150 | 2-DN100 | 6510 | 10510 | 4240 | 2200 | 4965 |
| BHX-135 | 135 | 4 | 3 | 45000 | 1 | 4 | 180 | 2-DN100 | 7100 | 11950 | 5610 | 2200 | 4220 |
| BHX-150 | 150 | 4 | 3 | 40000 | 1 | 4 | 180 | 2-DN100 | 7310 | 12160 | 5610 | 2200 | 4730 |
| BHX-165 | 165 | 4 | 4 | 45000 | 1 | 4 | 180 | 2-DN100 | 7590 | 12440 | 5610 | 2200 | 4965 |
| BHX-180 | 183 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 8920 | 15580 | 7450 | 2200 | 4220 |
| BHX-200 | 200 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 9330 | 15990 | 7450 | 2200 | 4720 |
| BHX-225 | 226 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 9550 | 16210 | 7450 | 2200 | 4965 |
| BHX-250 | 250 | 5 | 4 | 45000 | 2 | 4 | 180 | 4-DN100 | 11650 | 19090 | 9300 | 2200 | 4720 |
| BHX-265 | 265 | 5 | 4 | 45000 | 2 | 4 | 180 | 4-DN100 | 12350 | 19790 | 9300 | 2200 | 4965 |
| BHX-280 | 280 | 6 | 4 | 45000 | 2 | 4 | 180 | 4-DN100 | 12490 | 19930 | 9300 | 2200 | 4965 |
MODEL |
CAPACITY (M3/h) |
FAN |
WATER SPRAYING PUMP |
INLET/OUTLET DN(MM) |
WEIGHT |
DIMENSION |
|||||||
QTY |
POWER (K/W) |
AIR VOLUME PER SET (M3/h) |
QTY |
POWER (K/W) |
WATER VOLUME PER SET (M3/h) |
SHIPPING (KG) |
OPERATIONG (KG) |
LENGTH (MM) |
WIDTH (MM) |
HEIGHT (MM) |
|||
| BNX-10 | 12 | 1 | 1.5 | 18000 | 1 | 0.55 | 23 | DN50 | 890 | 1660 | 1230 | 1150 | 3440 |
| BNX-20 | 21 | 1 | 2.2 | 30000 | 1 | 0.75 | 28 | DN50 | 1370 | 2480 | 1925 | 1150 | 3650 |
| BNX-30 | 33 | 1 | 3 | 45000 | 1 | 0.75 | 28 | DN50 | 1990 | 3620 | 1925 | 1840 | 3840 |
| BNX-40 | 43 | 1 | 4 | 60000 | 1 | 1.1 | 45 | DN80 | 2120 | 3790 | 1925 | 1840 | 4220 |
| BNX-50 | 51 | 1 | 5.5 | 75000 | 1 | 1.5 | 65 | DN80 | 2420 | 4490 | 2470 | 1840 | 4220 |
| BNX-60 | 61 | 1 | 7.5 | 87000 | 1 | 1.5 | 65 | DN80 | 2690 | 4760 | 2470 | 1840 | 4450 |
| BNX-70 | 70 | 1 | 7.5 | 100000 | 1 | 2.2 | 84 | DN100 | 3650 | 6080 | 2790 | 1840 | 4450 |
| BNX-80 | 80 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN100 | 4150 | 7480 | 3770 | 1840 | 4220 |
| BNX-90 | 90 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN100 | 4680 | 8010 | 3770 | 1840 | 4450 |
| BNX-100 | 100 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN125 | 5120 | 8450 | 3770 | 1840 | 4450 |
| BNX-110 | 110 | 2 | 5.5 | 75000 | 1 | 3 | 120 | DN125 | 5360 | 9430 | 3770 | 2200 | 4220 |
| BNX-125 | 125 | 2 | 5.5 | 75000 | 1 | 3 | 120 | 2-DN100 | 5980 | 10050 | 3770 | 2200 | 4450 |
| BNX-135 | 135 | 2 | 5.5 | 87000 | 1 | 4 | 170 | 2-DN100 | 6230 | 11270 | 4846 | 2200 | 4350 |
| BNX-150 | 150 | 2 | 7.5 | 100000 | 1 | 4 | 170 | 2-DN100 | 6560 | 11590 | 4846 | 2200 | 4650 |
| BNX-165 | 165 | 3 | 4 | 65000 | 1 | 4 | 170 | 2-DN100 | 7850 | 13730 | 5610 | 2200 | 4350 |
| BNX-180 | 183 | 3 | 5.5 | 75000 | 1 | 4 | 170 | 2-DN125 | 8450 | 14330 | 5610 | 2200 | 4650 |
| BNX-200 | 200 | 3 | 5.5 | 75000 | 1 | 4 | 170 | 4-DN80 | 9180 | 15380 | 6046 | 2200 | 4650 |
| BNX-225 | 225 | 3 | 7.5 | 87000 | 1 | 5.5 | 230 | 4-DN80 | 9780 | 17340 | 7230 | 2200 | 4650 |
| BNX-250 | 250 | 4 | 5.5 | 75000 | 2 | 3 | 120 | 4-DN100 | 10860 | 18520 | 7450 | 2200 | 4650 |
| BNX-265 | 265 | 4 | 5.5 | 75000 | 2 | 4 | 170 | 4-DN100 | 11480 | 20880 | 9030 | 2200 | 4965 |
| BNX-280 | 280 | 4 | 5.5 | 75000 | 2 | 4 | 170 | 4-DN100 | 11720 | 21120 | 9030 | 2200 | 4965 |
1. Q: Are you a manufacturer or a trading company?
A: We are a leading cooling tower manufacturer with over 40 years of production experience. "HACST" and "Heng An" are well-known brands in China and internationally. We are a large group company based in Weifang, Shandong, China, with our own modern factory and R&D center.
2. Q: What is the difference between counter flow and cross flow cooling towers?
A: The main difference is the direction of airflow relative to water flow.
In counter flow towers, air flows vertically upward while water falls downward (opposite directions), making them more thermally efficient and compact.
In cross flow towers, air flows horizontally across the downward-falling water. Cross flow towers are often easier to maintain and better suited for certain space or water quality conditions.
We can recommend the best type based on your specific project needs.
3. Q: What is your Minimum Order Quantity (MOQ)?
A: Our MOQ is 1 set. We welcome both small trial orders and bulk wholesale inquiries.
4. Q: How do I get spare parts and how long does delivery take?
A: We have a complete spare parts workshop and can supply all components for our cooling towers, evaporative condensers, and adiabatic coolers.
90% of spare parts can be shipped to any location worldwide within one week.
5. Q: What if we don't have professional engineers for installation or maintenance?
A: No problem. We can dispatch experienced engineers to your site for installation, commissioning, and on-site training for your team on operation and maintenance.
6. Q: How can I choose the right cooling tower model for my project?
A: Please provide the following basic information and our technical team will recommend the most suitable model:
Application (e.g., HVAC, air compressor, melting furnace, data center, power plant, etc.)
Water flow rate (tons per hour)
Inlet water temperature
Outlet (cooled) water temperature
Local wet bulb temperature
Power supply (voltage & frequency)
We offer both standard and highly customized solutions.
7. Q: Do you support OEM/ODM and customized designs?
A: Yes. We specialize in tailor-made solutions according to your specific requirements, including special materials, dimensions, noise levels, or performance needs.
8. Q: What certifications do your products have?
A: Our products are certified with ISO9001, ISO14001, ISO45001, CTI, CE, TÜV, BV, SGS, AS1210, and China energy-saving & water-saving certifications.
9. Q: What is your delivery time?
A: Standard models are usually ready within 15-30 days. Customized products may take 30-45 days depending on complexity. We will confirm the exact lead time after receiving your detailed requirements.
10. Q: Do you provide after-sales service and technical support?
A: Yes. We offer full after-sales support, including remote technical guidance, spare parts supply, on-site service (if needed), and long-term maintenance advice. Our goal is to ensure your equipment runs efficiently for many years.
11. Q: How energy-efficient and water-saving are your cooling towers?
A: Our closed circuit cooling towers, adiabatic coolers, and evaporative condensers are designed for high efficiency and low water consumption. Many models help customers significantly reduce energy and water usage compared to traditional systems.