1) Standardized modular design ,easy in installation maintation.
2) Adopting advanced world famous brand components, drive parts, electric parts and operation parts.
3) Coil made of top quality seamless steel, high presure designed
4) Customized available
MODEL |
CAPACITY (M3/h) |
FAN |
WATER SPRAYING PUMP |
INLET/OUTLET DN(MM) |
WEIGHT |
DIMENSION |
|||||||
QTY |
POWER (K/W) |
AIR VOLUME PER SET (M3/h) |
QTY |
POWER (K/W) |
WATER VOLUME PER SET (M3/h) |
DN(mm) | SHIPPING (KG) |
OPERATIONG (KG) |
LENGTH (MM) |
WIDTH (MM) |
HEIGHT (MM) |
||
ZHX-320 | 320 | 1 | 3 | 35000 | 1 | 1.1 | 53 | DN80 | 2390 | 3790 | 1925 | 2380 | 4220 |
ZHX-430 | 430 | 1 | 4 | 45000 | 1 | 1.1 | 53 | DN100 | 2510 | 3910 | 1925 | 2380 | 4220 |
ZHX-525 | 525 | 1 | 5.5 | 65000 | 1 | 1.5 | 70 | DN100 | 2760 | 4340 | 1925 | 2580 | 4220 |
ZHX-595 | 595 | 1 | 5.5 | 75000 | 1 | 1.5 | 70 | DN100 | 3290 | 5140 | 1925 | 2900 | 4220 |
ZHX-700 | 700 | 1 | 7.5 | 87000 | 1 | 1.5 | 70 | DN100 | 3680 | 5530 | 1925 | 2900 | 4965 |
ZHX-800 | 800 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN100 | 4230 | 7650 | 3770 | 2200 | 4220 |
ZHX-870 | 870 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN125 | 4510 | 7930 | 3770 | 2200 | 4720 |
ZHX-980 | 980 | 2 | 4 | 45000 | 1 | 2.2 | 100 | DN125 | 4620 | 8040 | 3770 | 2200 | 4965 |
ZHX-1100 | 1100 | 3 | 3 | 40000 | 1 | 3 | 150 | DN125 | 6170 | 10170 | 4240 | 2200 | 4720 |
ZHX-1250 | 1250 | 3 | 4 | 45000 | 1 | 3 | 150 | 2-DN100 | 6510 | 10510 | 4240 | 2200 | 4965 |
ZHX-1380 | 1380 | 4 | 3 | 45000 | 1 | 4 | 180 | 2-DN100 | 7100 | 11950 | 5610 | 2200 | 4220 |
ZHX-1520 | 1520 | 4 | 3 | 40000 | 1 | 4 | 180 | 2-DN100 | 7310 | 12160 | 5610 | 2200 | 4730 |
ZHX-1680 | 1680 | 4 | 4 | 45000 | 1 | 4 | 180 | 2-DN100 | 7590 | 12440 | 5610 | 2200 | 4965 |
ZHX-1840 | 1840 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 8920 | 15580 | 7450 | 2200 | 4220 |
ZHX-2010 | 2010 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 9330 | 15990 | 7450 | 2200 | 4720 |
ZHX-2245 | 2245 | 4 | 4 | 45000 | 1 | 5.5 | 233 | 2-DN125 | 9550 | 16210 | 7450 | 2200 | 4965 |
ZHX-2450 | 2450 | 5 | 4 | 45000 | 1 | 4 | 180 | 4-DN100 | 11650 | 19090 | 9300 | 2200 | 4720 |
ZHX-2600 | 2680 | 5 | 4 | 45000 | 1 | 4 | 180 | 4-DN100 | 12350 | 19790 | 9300 | 2200 | 4965 |
ZHX-2820 | 2820 | 6 | 4 | 45000 | 1 | 4 | 180 | 4-DN100 | 12490 | 19930 | 9300 | 2200 | 4965 |
MODEL |
CAPACITY (M3/h) |
FAN |
WATER SPRAYING PUMP |
INLET/OUTLET DN(MM) |
WEIGHT |
DIMENSION |
|||||||
QTY |
POWER (K/W) |
AIR VOLUME PER SET (M3/h) |
QTY |
POWER (K/W) |
WATER VOLUME PER SET (M3/h) |
SHIPPING (KG) |
OPERATIONG (KG) |
LENGTH (MM) |
WIDTH (MM) |
HEIGHT (MM) |
|||
ZNX-100 | 100 | 1 | 1.5 | 18000 | 1 | 0.55 | 23 | DN50 | 890 | 1660 | 1230 | 1150 | 3440 |
ZNX-200 | 200 | 1 | 2.2 | 30000 | 1 | 0.75 | 28 | DN50 | 1370 | 2480 | 1925 | 1150 | 3650 |
ZNX-320 | 320 | 1 | 3 | 45000 | 1 | 0.75 | 28 | DN50 | 1990 | 3620 | 1925 | 1840 | 3840 |
ZNX-430 | 430 | 1 | 4 | 60000 | 1 | 1.1 | 45 | DN80 | 2120 | 3790 | 1925 | 1840 | 4220 |
ZNX-525 | 525 | 1 | 5.5 | 75000 | 1 | 1.5 | 65 | DN80 | 2420 | 4490 | 2470 | 1840 | 4220 |
ZNX-595 | 595 | 1 | 7.5 | 87000 | 1 | 1.5 | 65 | DN80 | 2690 | 4760 | 2470 | 1840 | 4450 |
ZNX-700 | 700 | 1 | 7.5 | 100000 | 1 | 2.2 | 84 | DN100 | 3650 | 6080 | 2790 | 1840 | 4450 |
ZNX-800 | 800 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN100 | 4150 | 7480 | 3770 | 1840 | 4220 |
ZNX-870 | 870 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN100 | 4680 | 8010 | 3770 | 1840 | 4450 |
ZNX-980 | 980 | 2 | 4 | 65000 | 1 | 2.2 | 84 | DN125 | 5120 | 8450 | 3770 | 1840 | 4450 |
ZNX-1100 | 1100 | 2 | 5.5 | 75000 | 1 | 3 | 120 | DN125 | 5360 | 9430 | 3770 | 2200 | 4220 |
ZNX-1250 | 1250 | 2 | 5.5 | 75000 | 1 | 3 | 120 | 2-DN100 | 5980 | 10050 | 3770 | 2200 | 4450 |
ZNX-1380 | 1380 | 2 | 5.5. | 87000 | 1 | 4 | 170 | 2-DN100 | 6230 | 11270 | 4846 | 2200 | 4350 |
ZNX-1520 | 1520 | 2 | 7.5 | 100000 | 1 | 4 | 170 | 2-DN100 | 6560 | 11590 | 4846 | 2200 | 4650 |
ZNX-1680 | 1680 | 3 | 4 | 65000 | 1 | 4 | 170 | 2-DN100 | 7850 | 13730 | 5610 | 2200 | 4350 |
ZNX-1840 | 1840 | 3 | 5.5 | 75000 | 1 | 4 | 170 | 2-DN125 | 8450 | 14330 | 5610 | 2200 | 4650 |
ZNX-2010 | 2010 | 3 | 5.5 | 75000 | 1 | 4 | 170 | 4-DN80 | 9180 | 15380 | 6046 | 2200 | 4650 |
ZNX-2245 | 2245 | 3 | 7.5 | 87000 | 1 | 5.5 | 230 | 4-DN80 | 9780 | 17340 | 7230 | 2200 | 4650 |
ZNX-2450 | 2450 | 4 | 5.5 | 75000 | 2 | 3 | 120 | 4-DN100 | 10860 | 18520 | 7450 | 2200 | 4650 |
ZNX-2600 | 2600 | 4 | 5.5 | 75000 | 2 | 4 | 170 | 4-DN100 | 11480 | 20880 | 9030 | 2200 | 4965 |
ZNX-2820 | 2820 | 4 | 5.5 | 75000 | 2 | 4 | 170 | 4-DN100 | 11720 | 21120 | 9030 | 2200 | 4965 |
Ammonia Refrigeration Cooling Evaporative Condenser for Mycom Compressor Cooling
1.Q: Your company is a manufacture or trading company?
A: We have been one of the largest leading cooling tower ,evaporative condenser and adiabatic cooler manufacturer since the year of 1975 with the "famous brand"-Heng An manufacture in China.
2.Q: How do I get repair parts and how long does it take?
A: We have workshop can supply all parts of the product, and 90% of spare parts can be distributed to any
place in the world within one week!
3.Q: What if I don't have the professional engineer to install or maintain the product?
A: We could send experience engineers on site to install the product and train your staff for equipment
operation and maintenance.
4.Q: How can I choose a suitable model?
A: As long as you provide the following information, we can assist to design and select the model for you.
What is the refrigerant and heat rejection :
Where is the location that our product are used?
What is the wet bulb temperature and condenser temperature ?
What is your requirement of the condensing coil material and casing material?