• Closed Circuit Counter Flow Small Water Cooling Tower System
  • Closed Circuit Counter Flow Small Water Cooling Tower System
  • Closed Circuit Counter Flow Small Water Cooling Tower System
  • Closed Circuit Counter Flow Small Water Cooling Tower System
  • Closed Circuit Counter Flow Small Water Cooling Tower System
  • Closed Circuit Counter Flow Small Water Cooling Tower System

Closed Circuit Counter Flow Small Water Cooling Tower System

After-sales Service: Online Support
Warranty: 18 Months
Cooling Method: Counter Flow
Ventilation Mode: Natural Ventilation
Material: SS304/316L,Gi,HDG
Air Contact Form: Wet and Dry
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
BNX-110
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial,Air Condition
Certification
ISO, CE
Condition
New
Cooling Type
Square Cooling Tower
Voltage
220-480V,50/60Hz
Fan Type
Axial Flow Type,Good Start Performance
Drift Rate
<0.005%
Motors
Simens/Weg Brand
Coil Material
SS304/316L,HDG,Red Copper
Application Industries
Food & Beverage Factory, Energy&Mining,Cehmical
Maintance
with Access Door and Ladder
Construction Material
SS304/316L,Galvanized Steel
Company Certification
CE ISO TUV
Service
Free Spare Parts&Technical Video Support
Packing
20′container,40′container,Low Your Cost
Installation
Upper Body and Bottom Body Two Parts
OEM
Accept
Material for Coil
Galvanized, Stainless Steel
Transport Package
Plastic Film Packed and Container
Specification
dimension: 3770*2200*4220mm
Trademark
HAC
Origin
Weifang City, Shandong Province, China
HS Code
8419500090
Production Capacity
2000set/Year

Product Description

BNX series Counter Flow Closed Circuit Cooling Tower
Principle of Operation: 
Closed Circuit Counter Flow Small Water Cooling Tower System

For BNX series counter flow type closed circuit cooling tower, the fresh air  intakes from bottom air inlet, and will beecome saturated hot air mixed with spraying water as they flow in reverse direction.The heat will be exhausted out by fans, but the warer will be collected to water basin for secondary sparaying by its special designed drift eliminate.As no infill inside, BNX series cooling tower has muchspace to enlarge its coil unit heatrejection area, the structure is more compact and requires less footprint. Especially, its suiable to the fluid with high temperature.
Closed Circuit Counter Flow Small Water Cooling Tower System

Closed circuit Cooling Tower are routinely selected for  numerous commerical and industrual process cooling applications,some examples include:
* Water-source heat pumps
* Self-contacined cooling units
* Chillers
* Hybrid evaporative/Dry cooling
* Cooling special fluids
* Compressor jacket cooling, intercooling, aftercooling
* Machine jacket cooling
* Induction furances

Closed Circuit Counter Flow Small Water Cooling Tower System
Closed Circuit Counter Flow Small Water Cooling Tower System

Main accessories
SS304/316L / Galvanzied steel / Red copper Coil.
Till now, the biggest operating pressure of coil we designed reach to 30 Mpa, far more  than  the competitors level.

Closed Circuit Counter Flow Small Water Cooling Tower System Closed Circuit Counter Flow Small Water Cooling Tower System
Closed Circuit Counter Flow Small Water Cooling Tower System

Simens/WEG brand Fans and Motors, Axial flow type, direct driven no belt, saving more energy than Centrifugal type.
IP 55&IP 56, Class F.
SS304 and Hot dip galvanized steel.
We can also offer EC and Explosion -proof motors.

Closed Circuit Counter Flow Small Water Cooling Tower System
Closed Circuit Counter Flow Small Water Cooling Tower System

Product Characteristics:
* Excelent Heat Exchange Performance
Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and improve the heat exchange performance.
* Convenient Maintenance
Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time.
* Convenient Transporation and Installlation

The Cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves transporattion and installation cost.
*Slope Water Basin Design
Suspended PVC fill and sloped water basin floor toward thge drain facilitate cleaning.
Closed Circuit Counter Flow Small Water Cooling Tower System
Closed Circuit Counter Flow Small Water Cooling Tower System

MODEL

CAPACITY(M3/h)

FAN

WATER SPRAYING PUMP

INLET/OUTLET DN(MM)

WEIGHT

DIMENSION

QTY &POWER(KW)

AIR VOLUME PER SET (M3/h)

QTY &POWER(KW)

WATER VOLUME PER SET (M3/h)

SHIPPING(KG)

OPERATIONG(KG)

LENGTH(MM)

WIDTH(MM)

HEIGHT(MM)
BNX-10 12 1*1.5 18000 1*0.55 23 DN50 890 1660 1230 1150 3440
BNX-20 21 1*2.2 30000 1*0.75 28 DN50 1370 2480 1925 1150 3650
BNX-30 33 1*3 45000 1*0.75 28 DN50 1990 3620 1925 1840 3840
BNX-40 43 1*4 60000 1*1.1 45 DN80 2120 3790 1925 1840 4220
BNX-50 51 1*5.5 75000 1*1.5 65 DN80 2420 4490 2470 1840 4220
BNX-60 61 1*7.5 87000 1*1.5 65 DN80 2690 4760 2470 1840 4450
BNX-70 70 1*7.5 100000 1*2.2 84 DN100 3650 6080 2790 1840 4450
BNX-80 80 2*4 65000 1*2.2 84 DN100 4150 7480 3770 1840 4220
BNX-90 90 2*4 65000 1*2.2 84 DN100 4680 8010 3770 1840 4450
BNX-100 100 2*4 65000 1*2.2 84 DN125 5120 8450 3770 1840 4450
BNX-110 110 2*5.5 75000 1*3 120 DN125 5360 9430 3770 2200 4220
BNX-125 125 2*5.5 75000 1*3 120 2-DN100 5980 10050 3770 2200 4450
BNX-135 135 2*5.5 87000 1*4 170 2-DN100 6230 11270 4846 2200 4350
BNX-150 150 2*7.5 100000 1*4 170 2-DN100 6560 11590 4846 2200 4650
BNX-165 165 3*4 65000 1*4 170 2-DN100 7850 13730 5610 2200 4350
BNX-180 183 3*5.5 75000 1*4 170 2-DN125 8450 14330 5610 2200 4650
BNX-200 200 3*5.5 75000 1*4 170 4-DN80 9180 15380 6046 2200 4650
BNX-225 225 3*7.5 87000 1*5.5 230 4-DN80 9780 17340 7230 2200 4650
BNX-250 250 4*5.5 75000 2*3 120 4-DN100 10860 18520 7450 2200 4650
BNX-265 265 4*5.5 75000 2*4 170 4-DN100 11480 20880 9030 2200 4965
BNX-280 280 4*5.5 75000 2*4 170 4-DN100 11720 21120 9030 2200 4965


WHY CHOOSE HAC PRODUCT?
* You want experience…
Experienced R&D team bring more than 40 years of process cooling & heating experience with knowledgeable application, product and service specialists available to discuss your needs. 

* You want someone who understands your process…
Provided with experience in a wide range of process cooling & heating industries. When you give us the chance, we will show the rich experience and get you the correct solution to your problems.

* You want a product that fits your unique needs…
Offer a wide range of standard units, what's more, our application specialists can suggest the customized units to meet unique needs.

* Our Warranty
All the products are passed strict test, and HACST provide 18 months guarantee since the date of bill of lading. During this guarantee period, HACST provide spare parts without any charge in case of quality discrepancy caused by us. If out of guarantee period, we still can charge the buyer cost price of spare parts and provide Technical Product support for customers.

* Our Service:
- OEM & ODM, or any other unique customized demands are acceptable.
- Any price inquiries or technical inquiries will be responded within 24 hours.
- Experienced technical engineers will give the model selection guide or help design the customized model.
- Detailed quotation scheme and system configuration will be provided to the customer together.
- The whole order process is tracked throughout:  
  Technical proposal communication → Order production → Performance test → Packaging→ Necessary documents confirmation → Transportation → Customs declaration → Shipping → Installation assistance(provide user manual or install video) → After-sales support. 
Buyer will receive the notification mail (include photos,  report or other documents) in each process.
- Besides the temperature control units, other install parts or auxiliary equipments is optional according to customers' requirements.
- All necessary installation documentation (e.g. Electrical diagram, User Manual) will be provided in both electronic copy and hard copy.
- Perfect after-sales service system, it's including: Technical guidance, detailed machine maintenance methods, troubleshooting solutions, regular return visit etc.
Closed Circuit Counter Flow Small Water Cooling Tower System

 

Send your message to this supplier

*From:
*To:
avatar Mr. Hengan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now