Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant

Product Details
Customization: Available
After-sales Service: Field Installation, Commissioning and Training
Warranty: 2 Years
Still deciding? Get samples of US$ 5000/set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
  • Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
Find Similar Products
  • Overview
  • Product Photos
  • Product Description
  • Product Parameters
  • Cooling Tower Structure
  • Working Principle
  • Production Process
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
BNX-200
Cooling Method
Counter Flow
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Water Drift Loss
Less Than 0.005%
Cooling Tower Coils
SS304, Copper, HDG
Cooling Tower Shell
SS304, Z700
Motor Brand
Siemens Weg
Cooling Capacity
10-1000 Tons/Hour
Voltage
220V~660V
Motor
Protection Class IP55, Insulation Class F
Character
Energy Saving and Easy Maintenance
OEM
Yes
Overseas Service
Available
Productivity
2000 Sets/Year
Transport Package
Standard Container Shipment
Specification
Size: 5610*2200*4680mm
Trademark
HACST
Origin
Shandong China
HS Code
8419500090
Production Capacity
1000 Sets Per Year

Packaging & Delivery

Package Size
500.00cm * 200.00cm * 200.00cm
Package Gross Weight
3000.000kg
Lead Time
20 days (1 - 5 set)
To be negotiated ( > 5 set)

Product Description

 Factory Price Water Coil Fan Square Closed type Cooling Tower for Ice Cream Machine

Product Photos

Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant

Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant

Product Description

1)  No infill designed,more compact structure, lower profile, lesss installation area required and easy for transport and installation
2) Suitable for severe environment as its structure, which could prevent from sand and dust. So it is widely used fin casting workshop, mining factories.
3) Suitable to high temperature fluid, because there is no pvc fill designed.
4) Freezing resistance, because there is no pvc fill to slow down the spraying water flow speed.

Product Parameters

 

MODEL

CAPACITY(M3/h)

FAN

WATER SPRAYING PUMP

WEIGHT

DIMENSION

QTY

POWER(K/W)

AIR VOLUME PER SET (M3/h)

QTY

POWER(K/W)

WATER VOLUME PER SET (M3/h)

SHIPPING(KG)

OPERATING(KG)

LENGTH(MM)

WIDTH(MM)

HEIGHT(MM)
BNX-10 12 1 1.5 18000 1 0.55 23 890 1660 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1370 2480 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 1990 3620 1925 1840 3840
BNX-40 43 1 4 60000 1 1.1 45 2120 3790 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 2420 4490 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 2690 4760 2470 1840 4450
BNX-70 70 1 7.5 100000 1 2.2 84 3650 6080 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 4150 7480 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 4680 8010 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 5120 8450 3770 1840 4450
BNX-110 110 2 5.5 75000 1 3 120 5360 9430 3770 2200 4220
BNX-125 125 2 5.5 75000 1 3 120 5980 10050 3770 2200 4450
BNX-135 135 2 5.5 87000 1 4 170 6230 11270 4846 2200 4350
BNX-150 150 2 7.5 100000 1 4 170 6560 11590 4846 2200 4650
BNX-165 165 3 4 65000 1 4 170 7850 13730 5610 2200 4350
BNX-180 183 3 5.5 75000 1 4 170 8450 14330 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 9180 15380 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 9780 17340 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 10860 18520 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 11480 20880 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 11720 21120 9030 2200 4965

Cooling Tower Structure

Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant

 

Working Principle

Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.

There are three main configurations of factory assembled cooling towers: combined flow, crossflow and counterflow. In crossflow cooling towers, the water flows vertically down the fill as air flows horizontally across. In counterflow cooling towers, the water flows vertically down the fill as air flows vertically up.
Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant

Production Process


Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant
 

Company Profile

Energy Saving Counter Flow Adiabatic Dry Closed Cooling Tower for Power Plant1.One of the biggest cooling tower & evaporative condenser manufacturers in China
2. Annual productivity 2100 sets
3. Supply OEM/ODM
4. Our products such as cooling tower, evaporative condenser, pvc fill have been exported to many countries such like America, Mexico, Malaysia, Chile, India, Dubai etc
5. Professionals:
We have 52 professionals working on product R&D area, 21 of th em have senior professional titles and 12 professionals have doctor degrees.
6.Capability:
Customize product based on different application areas, structures and materials. Analyze cooling system based on the data collected from the sample installed, and come up with the solution.Help end-users to solve the problems related to the cooling system.
7. Achievements:
12 national new product categories, 121 national patents and Provincial level technology research & innovation projects

FAQ


 1.Q: Your company is a manufacture or trading company?
A: We are a leading cooling tower manufacturer for 40 years. It is a "famous brand"-Heng An manufacture in China.
2.Q: How do I get repair parts and how long does it take?
A: We have workshop can supply all parts of the product, and 90% of spare parts can be distributed to any place in the world within one week!
3.Q: What if I don't have the professional engineer to install or maintain the product?
A: We could send experience engineers on site to install the product and train your staff for equipment operation and maintenance.

4.Q: How can I choose a suitable model cooling tower ?
    A: As long as you provide the following information, we can help select the model for you.
Application (Explanations: Where the cooling towers will be used for?
 e.g. for HAVC system, Air Compressors, Melting Furnaces, etc.)
Water Flow Rate (Explanations: How many Tons of water required per hour?)
Inlet Water Temp. (Explanations: Temperature of hot water to be cooled)
Outlet Water Temp. (Explanations: Temperature of cooled water, 
usually it shall be at least 3~4 °C higher than the wet-bulb temp.) 
 Wet-bulb Temp. (Explanations: Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers)
Power Supply (Explanations: 380V/3 Phases is standard, which we could have
 in stock, but for customized towers, the delivery time could be longer)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier