Customization: | Available |
---|---|
After-sales Service: | on-Site Installation |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 3000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Closed type Combined flow cooling tower
1-Excellent Heat Exchange Performance
Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and improve the heat exchange performance.
2-Convenient Maintenance
Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time.
3-Convenient Transportation and Installation
The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves
transportation and installation cost.
4-Slope Water Basin Design
Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning
Technical Database
MODEL | CAPACITY | FAN | PUMP | DIMENSION | ||||||
QTY | POWER | AIR VOLUM PER SET | QTY | POWER | WATER VOLUME PER SET | L | W | H | ||
BHX-30 | 30 | 1 | 3 | 135000 | 1 | 1.1 | 36 | 1925 | 2380 | 4220 |
BHX-40 | 40 | 1 | 4 | 45000 | 1 | 1.1 | 45 | 1925 | 2380 | 4220 |
BHX-50 | 50 | 1 | 5.5 | 65000 | 1 | 1.1 | 45 | 1925 | 2350 | 4220 |
BHX-60 | 60 | 1 | 5.5 | 75000 | 1 | 1.5 | 65 | 1925 | 2900 | 4220 |
BHX-70 | 70 | 1 | 7.5 | 87000 | 1 | 1.5 | 65 | 1925 | 2900 | 4965 |
BHX-80 | 80 | 2 | 4 | 45000 | 1 | 2.2 | 84 | 3770 | 2200 | 4220 |
BHX-90 | 90 | 2 | 4 | 45000 | 1 | 2.2 | 84 | 3770 | 2200 | 4720 |
BHX-100 | 100 | 2 | 4 | 45000 | 1 | 2.2 | 84 | 3770 | 2200 | 4965 |
BHX-110 | 110 | 3 | 3 | 40000 | 1 | 3 | 120 | 4240 | 2200 | 4720 |
BHX-125 | 125 | 3 | 4 | 45000 | 1 | 3 | 120 | 4240 | 2200 | 4965 |
BHX-135 | 135 | 4 | 3 | 45000 | 1 | 3 | 120 | 5610 | 2200 | 4220 |
BHX-150 | 150 | 4 | 3 | 40000 | 1 | 3 | 120 | 5610 | 2200 | 4730 |
BHX-165 | 165 | 4 | 4 | 45000 | 1 | 3 | 120 | 5610 | 2200 | 4965 |
BHX-183 | 183 | 4 | 4 | 5000 | 1 | 4 | 170 | 7450 | 2200 | 4220 |
BHX-200 | 200 | 4 | 4 | 45000 | 1 | 5.5 | 230 | 7450 | 2200 | 4730 |
BHX-226 | 226 | 4 | 4 | 45000 | 1 | 5.5 | 230 | 7450 | 2200 | 4965 |
BHX-250 | 250 | 5 | 4 | 45000 | 1 | 5.5 | 230 | 9300 | 2200 | 4720 |
BHX-265 | 265 | 5 | 4 | 45000 | 1 | 5.5 | 230 | 9300 | 2200 | 4965 |
BHX-280 | 280 | 6 | 4 | 45000 | 1 | 5.5 | 230 | 9300 | 2200 | 4965 |
Couner Flow Cooling Tower | ||||||||||
MODEL | CAPACITY (kW) |
FAN | PUMP | DIMENSION (mm) | ||||||
QTY | POWER (kW) | AIR VOLUM PER SET (m3/h) | QTY | POWER (kW) | WATER VOLUME PER SET(m3/h) | Lenth | Width | Height | ||
BNX-07 | 8 | 1 | 0.75 | 15000 | 1 | 0.37 | 16 | 1230 | 1150 | 3180 |
BNX-10 | 12 | 1 | 1.5 | 18000 | 1 | 0.55 | 23 | 1230 | 1150 | 3440 |
BNX-20 | 21 | 1 | 2.2 | 30000 | 1 | 0.75 | 28 | 1925 | 1150 | 3650 |
BNX-30 | 33 | 1 | 3 | 45000 | 1 | 1.1 | 53 | 1925 | 1840 | 3840 |
BNX-40 | 43 | 1 | 4 | 60000 | 1 | 1.1 | 53 | 1925 | 1840 | 4220 |
BNX-50 | 51 | 1 | 5.5 | 75000 | 1 | 1.5 | 70 | 2470 | 1840 | 4220 |
BNX-60 | 61 | 1 | 7.5 | 87000 | 1 | 1.5 | 70 | 2470 | 1840 | 4450 |
BNX-70 | 70 | 1 | 7.5 | 100000 | 1 | 2.2 | 84 | 2790 | 1840 | 4450 |
BNX-80 | 80 | 2 | 4 | 65000 | 1 | 2.2 | 100 | 3770 | 1840 | 4020 |
BNX-90 | 90 | 2 | 4 | 65000 | 1 | 2.2 | 100 | 3770 | 1840 | 4220 |
BNX-100 | 100 | 2 | 4 | 65000 | 1 | 2.2 | 100 | 3770 | 1840 | 4450 |
BNX-110 | 110 | 2 | 5.5 | 75000 | 1 | 3 | 120 | 3770 | 2200 | 4220 |
BNX-125 | 125 | 2 | 5.5 | 75000 | 1 | 3 | 120 | 3770 | 2200 | 4450 |
BNX-135 | 135 | 2 | 5.5 | 87000 | 1 | 4 | 180 | 4846 | 2200 | 4350 |
BNX-150 | 150 | 2 | 7.5 | 100000 | 1 | 4 | 180 | 4846 | 2200 | 4650 |
BNX-165 | 165 | 3 | 4 | 65000 | 1 | 5.5 | 230 | 5610 | 2200 | 4350 |
BNX-180 | 183 | 3 | 5.5 | 75000 | 1 | 5.5 | 230 | 5610 | 2200 | 4650 |
BNX-200 | 200 | 3 | 5.5 | 80000 | 1 | 5.5 | 230 | 5610 | 2200 | 4680 |
BNX-225 | 225 | 3 | 7.5 | 87000 | 2 | 3 | 120 | 6510 | 2200 | 4650 |
BNX-250 | 250 | 4 | 5.5 | 75000 | 2 | 3 | 120 | 7230 | 2200 | 4650 |
BNX-265 | 265 | 4 | 5.5 | 75000 | 2 | 3 | 120 | 7450 | 2200 | 4650 |
BNX-280 | 280 | 4 | 5.5 | 75000 | 2 | 3 | 150 | 8050 | 2200 | 4965 |
BNX-300 | 300 | 4 | 7.5 | 87000 | 2 | 4 | 180 | 8640 | 2200 | 4965 |
Product Details
Who We Are
HACST is a leading global manufacturer of cooling towers, evaporative condensers and air-cooled heat exchangers providing full-service cooling solutions and support to customers in the heating, industrial, refrigeration and process cooling markets for 45 years.
The company's main products include open and closed circuit cooling tower, evaporative condenser, air cooled heat exchanger, nano fluid heat exchanger, etc. Products are widely used in petroleum, chemical industry, pharmaceutical, coal, electric power, steel and other fields.
After more than ten years of hard work, we have a mature and stable cooperative customer base in many countries around the world. Products have been exported to more than 60 countries and regions including the United States, Russia,Germany, France, Belgium, Australia, Latin America, the United Arab Emirates, Saudi Arabia,Pakistan,India,and Southeast Asia.
The company has upgraded from standardized products to the most complex customized products, tailor-made according to the specific requirements of customers, and provide the best design solutions. The company has a sound quality management system, strict manufacturing process, perfect testing methods and after-sales service system. The company has successively passed ISO9001 quality management, ISO14001 environmental management, OHSAS18001 occupational health and safety management and other system certifications,production license for Class D pressure vessels. It has a number of inventions and patents. The company's products have passed international testing organizations:CTI,Australian AS1210 Pressure Vessel Certification,German TUV company, French BV company, and Europe CE certification. Product quality and service are highly recognized and praised by domestic and foreign customers.
1 Q: Is your company a manufacture or a trading company?
A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975.
The famous brand-"Heng An" is well known not only China but all over the world.
As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.
2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?
A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
At same situation, counter flow tower are inherently more efficient than cross flow tower.
3 Q: How do you get repair parts and how long does it take?
A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.
4 Q: What if you don't have the professional engineers to install or maintain the tower?
A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince.
5 Q: How can I choose a suitable cooling tower?
A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.
Application | Which industry or system using for? For example, HAVC system, casting cooling system |
Water flow capacity | How many tons of water treatment per hour? |
Inlet water temp. | Tempreture of hot water to be cooled |
Outlet water temp. | Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture. |
Wet bulb temp. | Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers. |
Power supply | The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer. |