Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

Product Details
Customization: Available
After-sales Service: 24 Months
Warranty: 24 Months
Still deciding? Get samples of US$ 10000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
  • Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Find Similar Products
  • Overview
  • Product Description
  • Project
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
BHX
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC, CTI
Condition
New
Shape
Square
Type
Counterflow, Combined Flow, Cross Flow
Casing Material
Aluminum-Zinc Alloy Steel Plate, SS304, SS316L
Casing Thickness
2mm
Coil Thickness
1.0mm, 1.2mm, 1.5mm
Coil Shape
Oval, Round
Coil Matreial
Galvanized, SS304, SS316L, Copper
Motor for Fan
Weg, Siemense
Motor for Pump
Weg, Siemense
Fan Type
Axial Flow Type
Maintance
with Access Door and Ladder
Pump Type
Centrifugal Pump
OEM
Accept
Fill
PVC
Drift Eliminator
PVC
Transport Package
Safety Film
Specification
3770*2200*4220mm
Trademark
HACST
Origin
China
HS Code
841989
Production Capacity
2000sets/Year

Packaging & Delivery

Package Size
377.00cm * 220.00cm * 200.00cm
Package Gross Weight
2000.000kg
Lead Time
35 days (1 - 1 Pieces)
40 days (2 - 3 Pieces)
45 days (4 - 5 Pieces)
To be negotiated ( > 5 Pieces)

Product Description

Product Description

What is a cooling tower?
Cooling towers offer a proven and cost-effective solution for rejecting heat from condenser water and industrial processes. During operation, the condenser water or process water flows directly over the heat transfer surface of the cooling tower. As air is introduced into the tower, a fraction of this water is evaporated, cooling the remaining water.

Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

Principle of Operation
Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.

Configuration
There are three main configurations of factory assembled cooling towers: combined flow, crossflow and counterflow. In crossflow cooling towers, the water flows vertically down the fill as air flows horizontally across. In counterflow cooling towers, the water flows vertically down the fill as air flows vertically up.

Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Spare parts of cooling tower
Pump, fan, heat exchange coil, PVC fill, drift eliminator, air inlet louver, nozzle
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Cooling tower parts fan
A. Top famous brand, special designed for cooling tower.
C. Axial fan mounted on top of cooling tower. Removable protective nets set in the side of the wind turbine.
D. Motor is adopted with outdoor and waterproof, mechanical seal, protection IP55, insulation class F; 
E. Fan characteristic parameters meet design conditions, all blades with high quality process and reliable, smooth surface, each section transition uniform, no cracks, nicks, burrs; The gap of blade between the evaporative condenser inner shell are same, and fans get through dynamic and static balance test and torque balance test. Fans rigorous static and dynamic balance need to be corrected before delivery, no chattering. 
Cooling tower parts puymp
A. Spray Pump: The spraying pump is special designed for cooling tower, which with high flow, low head, high efficiency, low noise, low power and energy saving advance. Special designed for close cooling tower. Pump motor with protection class IP55, insulation class F.
B. Spraying Water Pipe: made of PVC material, with flowing advantages: easy cold, bear high pressure, anti-corrosion, anti-collision, and water resistant. All spraying manifolds are adopted removable type, more easy to replace and clean it.  

 
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

Combined flow cooling tower characteristics:
1. Excellent Heat Exchange Performance
Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and improve the heat exchange performance.
2. Convenient Maintenance
Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time. 
3. Convenient Transportation and Installation
The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves transportation and installation cost.
4. Slope Water Basin Design
Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

Counter flow cooling tower advantages:
1. No infill designed, more compact structure, lower profile, less installation area required, and easy for transport and installation.
2. Suitable to severe environment as its structure much more close, which could prevent from sand and dust. So it widely used for casting workshop,mining factory etc. 
3. Suitable to high temperature fluid, because hot spraying water will not distort PVC fill as no PVC fill designed.
4. Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
 
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Coil material Galvanized steel/stainless steel/red copper
Casing material Al-Zn alloy coated steel sheet/stainless steel
Fan type Axial flow type
Cooling tower fill 100% original PVC material
Drift eliminator Special designed anti-corrosion PVC
Water flow loss Less than 0.005%
Maintenance with access door and ladder
Noise Control Low speed fan, noise damping
Fan & water pump motor Siemens, WEG
Customization Yes

 

Production Process
Tube bending  → Coil automatic welding → Coil assembly → Cutting plate → Plate assembly → bottom parts assembly → installation coil → top parts assembly →  complete unit → loading to container → Running in customer plant

Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Project

Application of cooling tower

Closed Circuit Cooling Towers are routinely selected for numerous commercial and industrial process cooling applications. Some examples include:
1 Water-source heat pumps
2 Self-contained cooling units
3 Chillers
4 Hybrid evaporative /Dry cooling
5 Cooling special fluids
6 Compressor jacket cooling,intercooling ,aftercooling
7 Machine jacket cooling
8 Induction furances
Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center
Company Profile

Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

FAQ


1. What is our main product ?
As a factory, our main products have cooling tower, evaporative condenser, and air cooler
2. How can I choose a suitable model of cooling tower? 
As long as you provide the following information, we can help select the model for you:
Inlet temperature, Outlet temperature, Wet bulb temperature, water flow rate.

3. When can I get the price?
We usually offer the quotation within one work days.
4. What is the Trade Term?
We accept Ex-work factory , FOB Qingdao, CNF or CIF, as your requirement. 
5. What is the Payment term?
T/T or L/C at sight.
6. What are your terms of packing?
Packing: export worthy package suitable for container transportation.
7. Do you test all your goods before delivery?
Yes, we have 100% test before delivery.
8. Can we do our OEM logo?
Yes.
9. The certificate you have?
CTI, ISO, CE, and so on

Stainless Steel Square Water Industrial Fluid Cooling Tower for Data Center

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier