CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry

Product Details
Customization: Available
After-sales Service: Provide
Warranty: 2 Years
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
  • CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
  • Our Service
  • Working Principles
  • FAQ
Overview

Basic Info.

Model NO.
BNX series
Cooling Method
Counter Flow
Ventilation Mode
Natural Ventilation
Material
Metal
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
MOQ
1 Set
Product Material
Carbon Steel,Stainless Steel
Coil Material
Carbon Steel,Stainless Steel
Fan Type
Axial Flow Fan,Ec Fan,etc
Fan Motor Brand
Weg,,Siemens,etc
Base Material
Carbon Steel,Stainless Steel
Fill Material
PVC,PP,CPVC
Drift Eliminator Material
PVC, Aluminum Alloy
Transport Package
Contatiner
Specification
2470*1840*4220
Trademark
HACST
Origin
China
Production Capacity
5000

Product Description


 
Product Description

 BNX Series Counter Flow Closed Cooling Tower Advantages:
 

1.No infill designed, more compact structure, lower profile, less installation area required, and easy for transport and
installation.

2.Suitable to severe environment as its structure much more close, which could prevent from sand and dust. So it widely used for casting workshop,mining factory etc.
 
3.Suitable to high temperature fluid, because hot spraying water will not distort PVC fill as no PVC fill designed.

4.Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.
Detailed Photos


CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry

Product Parameters
Type Capacity (M3/H) Qty Power(KW) Water Volime Perset(M3/H) Shiping(KG) Operating(KG) Length(MM) Width(MM) Height(MM)
BNX-10 12 1 0.55 23 890 1660 1230 1150 3440
BNX-20 21 1 0.75 28 1370 2480 1925 1150 3650
BNX-30 33 1 0.75 28 1990 3620 1925 1840 3840
 
Company Profile
We, Weifang Heng An Imp&Exp Co.,Ltd (HACST Brand). Are one of the largest manufacturer  of cooling tower ,evaporative condenser ,dry condenser and related spare parts as so on, in China since theyear of 1975 and we have been long terms OEM suppliers tor Baudouin ,CNPC ,Deutz ,Doosan ,Hitachi ,SRF ,Fuwei Films ,Hengli Group ,Mycom and Hamon and we could develop the custom designbased on the request of our customers to fully satisfy the cooling capacity request of our customers .


1.Our team provides a quick response within 12 hours, ensuring prompt support whenever you need it.


2.Our experienced engineers are available for overseas installation and commissioning, ensuring a smooth and successful setup.

3.We offer free training for refrigeration operators, helping you maximize the efficiency and lifespan of your equipment.

4.Timely supply of spare parts, minimizing downtime and ensuring continuous operation.

5.Choose our evaporative condenser for a reliable, efficient, and cost-effective cooling solution, backed by our commitment to quality, service, and customer satisfaction.
 
Contact us today to learn more! HOT! HOT! HOT!

CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for IndustryCTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry

Our Service

Our products, not only have won wide acclaim and stable customer groups in the domestic market, but also have successfully crossed the geographical boundaries and are exported to many overseas countries and regions, by virtue of excellent quality, innovative design and perfect after-sales service.

 
From the east of Asia to the west of Europe, from the continent of Africa to the coast of America, our products are everywhere. They have won the trust and love of consumers around the world with their reliable performance and excellent user experience.
 
HACST has become a bridge connecting different cultures and markets, and also marks the continuous improvement of our brand influence and international market competitiveness.
CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry

 
Working Principles

 For BNX series counter flow type closed circuit cooling tower:


Fresh air intakes from bottom air inlet ,Air will become saturated hot air mixed with spraying water as they flow in reverse direction,The heat will be exhausted out by fans, Water will be collected to water basin for secondary spraying by its special designed drift eliminator.

As no infill inside, BNX series cooling tower has much space to enlarge its coil unit heat rejection area, the structure is more compact and requires less footprint. 
CTI CE ISO Certified Counter Flow Closed Cooling Tower Customized Stainless Steel for Industry
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier