After-sales Service: on-Site Installation
Warranty: 2 Years
Cooling Method: Counter Flow/Cross Flow/Combined Flow
Ventilation Mode: Mixing Ventilation
Material: Metal
Air Contact Form: Wet and Dry
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Overview
  • Product Description
  • Working Principles
  • Product Parameters
  • Detailed Photos
  • Production Process
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE
Condition
New
Product
Closed Combined Flow Evaporative Condenser
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/ABB/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Advantage
Water Saving
Structure
Compact
Application
Food Industry and Chemical Medicine
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Product Description

Product Description

In data centers, cooling towers play a crucial role in maintaining optimal operating temperatures for servers and other IT equipment. Here's how cooling towers are typically used in data center applications:

1. Heat Dissipation: Data centers generate a significant amount of heat due to the operation of servers, storage devices, networking equipment, and other hardware. Cooling towers help dissipate this heat by transferring it from the data center to the atmosphere through the process of evaporation.

2. Chiller Systems: Many data centers use chiller systems in conjunction with cooling towers to provide chilled water for cooling purposes. Chilled water is circulated through the data center to absorb heat from the IT equipment, and then it is pumped to the cooling towers.

3. Water Cooling: Cooling towers use water as the primary cooling medium. Chilled water from the chiller system is circulated through the cooling towers, where it comes into contact with ambient air. As the water evaporates, it absorbs heat from the circulating water, cooling it down before it is returned to the data center for another cycle.

4. Energy Efficiency: By utilizing cooling towers in combination with chiller systems, data centers can achieve energy-efficient cooling solutions. Cooling towers provide free cooling using ambient air, reducing the load on mechanical refrigeration systems and saving

 

Closed Circuit cooling tower
Combined Flow Cooling Tower
Industrial Evaporative Cooler Evaporative Condenser for Data Center
Counter Flow Cooling Tower
Industrial Evaporative Cooler Evaporative Condenser for Data Center
Working Principles

 

Working PrincipleIndustrial Evaporative Cooler Evaporative Condenser for Data Center


 

Product Parameters

Technical Database

Combined Flow Cooling Tower
MODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BHX-30 30 1 3 135000 1 1.1 36 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 45 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.1 45 1925 2350 4220
BHX-60 60 1 5.5 75000 1 1.5 65 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 65 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 84 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 84 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 84 3770 2200 4965
BHX-110 110 3 3 40000 1 3 120 4240 2200 4720
BHX-125 125 3 4 45000 1 3 120 4240 2200 4965
BHX-135 135 4 3 45000 1 3 120 5610 2200 4220
BHX-150 150 4 3 40000 1 3 120 5610 2200 4730
BHX-165 165 4 4 45000 1 3 120 5610 2200 4965
BHX-183 183 4 4 5000 1 4 170 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 230 7450 2200 4730
BHX-226 226 4 4 45000 1 5.5 230 7450 2200 4965
BHX-250 250 5 4 45000 1 5.5 230 9300 2200 4720
BHX-265 265 5 4 45000 1 5.5 230 9300 2200 4965
BHX-280 280 6 4 45000 1 5.5 230 9300 2200 4965
Counter Flow Cooling Tower
ODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BNX-10 12 1 1.5 18000 1 0.55 23 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 1925 1840 3840
BNX-40 42 1 4 60000 1 1.1 45 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 2470 1840 4450
BNX-70 70 1 7.5 10000 1 2.2 84 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 3770 1840 4220
BNX-110 110 2 5.5 75000 1 3 120 3770 2200 4450
BNX-125 125 2 5.5 75000 1 3 120 3770 2200 4350
BNX-135 135 2 5.5 87000 1 4 170 4846 2200 4650
BNX-150 150 2 7.5 100000 1 4 170 4846 2200 4350
BNX-165 165 3 4 65000 1 4 170 5610 2200 4650
BNX-180 183 3 5.5 75000 1 4 170 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 9030 2200 4965
 
Detailed Photos

 

Product Details
Combined Flow Cooling Tower
Industrial Evaporative Cooler Evaporative Condenser for Data CenterCounter Flow Cooling Tower
 Industrial Evaporative Cooler Evaporative Condenser for Data Center          
Production Process

Production Process

Industrial Evaporative Cooler Evaporative Condenser for Data Center
Certifications

Industrial Evaporative Cooler Evaporative Condenser for Data Center
Packaging & Shipping

Shipment Procedures
Industrial Evaporative Cooler Evaporative Condenser for Data Center
Projects

Industrial Evaporative Cooler Evaporative Condenser for Data Center
Customer Visiting and Exhibition
Industrial Evaporative Cooler Evaporative Condenser for Data CenterIndustrial Evaporative Cooler Evaporative Condenser for Data Center
Cooperated Partner
Industrial Evaporative Cooler Evaporative Condenser for Data Center
FAQ

 

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
50
Year of Establishment
2012-01-13