Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant

Product Details
Customization: Available
After-sales Service: on-Site Installation
Warranty: 2 Years
Still deciding? Get samples of US$ 3000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
  • Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Projects and Partners
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Product
Closed Combined Flow Cooling Tower
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/Ab B/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Casing
SS304/Galvanized Sheet
Structure
SS304/Galvanized Steel
Fills
PP/PVC/SS304
Fan Blade
Pag/Aluminum/SS304
Pump Brand
Cnp/East/Kaiquan
Shape
Round/Square
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Packaging & Delivery

Package Size
3770.00cm * 2200.00cm * 4550.00cm
Package Gross Weight
5000.000kg

Product Description

 
Product Description


Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
 

Closed type Combined flow cooling towerWater Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant

Closed circuit cooling tower provides many operational and maintenance benefits to the user by keeping the process fluid in
a clean, closed loop.

 

Protect process fluids from contamination

Maximize system efficiency by reducing fouling and scaling tendencies

Reduce system energy costs

Reduce system maintenance costs

 

Product Characteristics:

Excellent Heat Exchange Performance

Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation,
and improve the heat exchange performance.

 

Convenient Maintenance

Huge maintenance space makes it convenient to inspect the product.Technicians can enter cooling tower during operation time.

 

Convenient Transportation and Installation

The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately
and saves transportation and installation cost.

 

Slope Water Basin Design

Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning.


Working PrincipleWater Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant

BHX Combined Flow Closed Circuit Cooling Tower Principle of Operation.

The process fluid to be cooled is circulated within a serpentine cooling coil, which is continually wetted on the outside by the
spraying water system. The heat is transferred by the wall of coil, becomes saturated steam when it meets spray water and air.
Then the heat will be discharged into atmosphere by fan, but water will be collected in the basin by drift eliminator for
recirculated spraying. The temperature of spraying water is reduced by PVC fill. spraying water flows in the same direction as
the fresh air, to cool coil mainly by significant heat conduction way, which is especially suitable to the cases when cooling
tower outlet temperature is much closer to the wet bulb temperature.

 

Notes of selecting a cooling tower as below:
1. The structure materials of cooling tower should be stable, durable, corrosion-resistant, and its assembly should be precise.

2. In the cooling tower,  it should be uniform water distribution, small fluid flow on the wall, the reasonably selected splash device, and it should not be easily blocked.

3. The type of cooling tower water filling should meet the requirements of water quality and water temperature.

4. The fan is should be long-term normal operation without vibration and abnormal noise, and the blades have good water erosion resistance and sufficient strength. The installation angle of the fan blades is adjustable, but the angle must be consistent, and the current of the motor does not exceed the rated current of the motor.

5. Low power consumption and low cost, small and medium-sized steel frame glass cooling towers also require light weight.

6. Cooling towers should be installed away near heat sources, exhaust gas and flue gas generation points, chemical storage areas and coal piles.

7. About the distance between cooling towers, between towers and other buildings, in addition to considering the ventilation requirements between the towers and the mutual influence between towers and buildings, we should also consider the safety distance of building fire prevention and explosion prevention, the construction and maintenance requirements of cooling towers.

8. The water inlet pipe direction of the cooling tower can be rotated at 90°, 180°and 270°.

9. The material of the cooling tower can withstand low temperatures of -50 ºC, but for areas where the average temperature of the coldest month is below -10ºC, it should be stated when ordering so that anti-icing measures can be taken. The cost of the cooling tower increases by about 3%.

10. The turbidity of the circulating water is not more than 50mg/l, and not more than 100mg/l in the short term. It should not contain oil and mechanical impurities. Algae removal and water quality stabilization measures should be taken when necessary.

11. The water distribution system is designed according to the nominal water volume. If the actual water volume differs from the nominal water volume by more than ±15%, it should be stated when ordering so that the design can be modified.

12. During the storage and transportation of cooling tower parts, heavy objects shall not be placed on them, they shall not be exposed to the sun, and attention shall be paid to fire prevention. During the installation, transportation and maintenance of cooling towers, open flames such as electric and gas welding shall not be used, and firecrackers and fireworks shall not be set off nearby.

13. For the design of multiple round towers, the net distance between towers should be maintained at no less than 0.5 times the diameter of the tower body. Cross flow towers and counter flow square towers can be arranged in parallel.

14. The water pump should be matched with the cooling tower capacity to meet the process requirements such as flow rate and head.

15. When selecting multiple cooling towers, try to choose the same model.

 
Product Parameters

Technical Database

Couner Flow Cooling Tower                  
MODEL CAPACITY
(kW)
FAN PUMP DIMENSION (mm)
QTY POWER (kW) AIR VOLUM PER SET (m3/h) QTY POWER (kW) WATER VOLUME PER SET(m3/h) Lenth Width Height
BNX-07 8 1 0.75 15000 1 0.37 16 1230 1150 3180
BNX-10 12 1 1.5 18000 1 0.55 23 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1925 1150 3650
BNX-30 33 1 3 45000 1 1.1 53 1925 1840 3840
BNX-40 43 1 4 60000 1 1.1 53 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 70 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 70 2470 1840 4450
BNX-70 70 1 7.5 100000 1 2.2 84 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 100 3770 1840 4020
BNX-90 90 2 4 65000 1 2.2 100 3770 1840 4220
BNX-100 100 2 4 65000 1 2.2 100 3770 1840 4450
BNX-110 110 2 5.5 75000 1 3 120 3770 2200 4220
BNX-125 125 2 5.5 75000 1 3 120 3770 2200 4450
BNX-135 135 2 5.5 87000 1 4 180 4846 2200 4350
BNX-150 150 2 7.5 100000 1 4 180 4846 2200 4650
BNX-165 165 3 4 65000 1 5.5 230 5610 2200 4350
BNX-180 183 3 5.5 75000 1 5.5 230 5610 2200 4650
BNX-200 200 3 5.5 80000 1 5.5 230 5610 2200 4680
BNX-225 225 3 7.5 87000 2 3 120 6510 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 7230 2200 4650
BNX-265 265 4 5.5 75000 2 3 120 7450 2200 4650
BNX-280 280 4 5.5 75000 2 3 150 8050 2200 4965
BNX-300 300 4 7.5 87000 2 4 180 8640 2200 4965



Product Details
The Combinedflow cooling tower has 5 main parts to support its operation.They are Fan&Motor,Spray Pump,Condenser Coil and PVC Fills as the pocture shows.

Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
                                            Water Saving Combine Flow Closed Loop Cooling Tower for Refinery PlantWater Saving Combine Flow Closed Loop Cooling Tower for Refinery PlantWater Saving Combine Flow Closed Loop Cooling Tower for Refinery PlantWater Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
 
Company Profile

Who We Are


Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Production Process

Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Packaging & Shipping

Shipment Procdures


Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant

 
Projects and Partners

Projects


Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Customer Visiting and Exhibition

Water Saving Combine Flow Closed Loop Cooling Tower for Refinery PlantWater Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
Cooperated Partner

Water Saving Combine Flow Closed Loop Cooling Tower for Refinery Plant
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier