Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System

Product Details
Customization: Available
After-sales Service: on-Site Installation
Warranty: 2 Years
Still deciding? Get samples of US$ 3000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
  • Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Projects and Partners
  • FAQ
Overview

Basic Info.

Model NO.
BHX
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Product
Closed Combined Flow Cooling Tower
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/Ab B/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Shape
Square
Structure
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Casing
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Infills
PVC/PP
Drift Eliminator
PVC/PP
Fan Duct
FRP/SS304/Carbon Steel
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Packaging & Delivery

Package Size
3770.00cm * 2200.00cm * 4568.00cm
Package Gross Weight
8000.000kg

Product Description

 
Product Description

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System

Closed type Combined flow cooling tower

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Working Principle
Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Advantages

1-Excellent Heat Exchange Performance

Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and improve the heat exchange performance.
2-Convenient Maintenance
Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time.
3-Convenient Transportation and Installation
The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves
transportation and installation cost.

4-Slope Water Basin Design
Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning


Product Characteristics:

  • Excellent Heat Exchange Performance

Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and

improve the heat exchange performance.

  • Convenient Maintenance

Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time.

  • Convenient Transportation and Installation

The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves

transportation and installation cost.

  • Slope Water Basin Design

Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning

 
Product Parameters

 

Technical Database
MODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BHX-30 30 1 3 135000 1 1.1 36 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 45 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.1 45 1925 2350 4220
BHX-60 60 1 5.5 75000 1 1.5 65 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 65 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 84 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 84 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 84 3770 2200 4965
BHX-110 110 3 3 40000 1 3 120 4240 2200 4720
BHX-125 125 3 4 45000 1 3 120 4240 2200 4965
BHX-135 135 4 3 45000 1 3 120 5610 2200 4220
BHX-150 150 4 3 40000 1 3 120 5610 2200 4730
BHX-165 165 4 4 45000 1 3 120 5610 2200 4965
BHX-183 183 4 4 5000 1 4 170 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 230 7450 2200 4730
BHX-226 226 4 4 45000 1 5.5 230 7450 2200 4965
BHX-250 250 5 4 45000 1 5.5 230 9300 2200 4720
BHX-265 265 5 4 45000 1 5.5 230 9300 2200 4965
BHX-280 280 6 4 45000 1 5.5 230 9300 2200 4965
 

Notes:
1.Do not use for construction. This brochure includes data current at the time of publication which should be reconfirmed at the time of purchase
2.All location dimensions for coil connections are approximate and should not be used for prefabrication of connecting piping.
3.Design conditions:wet bulb temperature 28.2ºC,inlet water temperature 37ºC,outlet water temperature 32ºC



Product Details
Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
                                              The Combinedflow cooling tower has 5 main parts to support its operation.
                                      
They are Fan&Motor,Spray Pump,Condenser Coil and PVC Fills as the pocture shows.
 
Company Profile

 

Who We Are
 

HACST is a leading global manufacturer of cooling towers, evaporative condensers and air-cooled heat exchangers.Providing full-service cooling solutions and support to customers in the heating, industrial, refrigeration and process cooling markets in China since the year of 1975.

HACST is a state level high-tech enterprise and one of the largest heat exchanger manufacturers in China, with a state-level testing laboratory and three large plants. It's the first one in the industry gets ISO9001 Quality Management System Certification and TS16949 Quality Management System Certification.


Production Process

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Shipment Procdures

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Projects and Partners

 

Projects

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Customer Visiting and Exhibition

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar SystemAluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
Cooperated Partner

Aluminum-Zinc Plate Closed Circuit Cooling Tower for Solar System
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier