Type: Water-Cooled
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Single-speed Fan
Noise Level: Low
Application Fields: Food Processing
Samples:
US$ 15000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)

Basic Info.

Certification
ISO, CE
Condition
New
Product Name
Stainless Steel Closed Loop Cooling Tower
Warranty
24 Months
Codenser Coils Material
Hot DIP Galvanised Steel, SS304, SS316L
Casing Material
Aluminum Zinc Sheet, SS304, SS316L
Fan/ Pump Motor
Weg, Siemens, Ect
Drift Eliminator Material
PVC
Application
Water Chiller, Furnace, Compressor, Ect
Fan Material
Hot DIP Galvanised Steel, SS304, SS316L
Transport Package
20feet/40feet Container
Specification
5610*2200*4730mm
Trademark
HACST
Origin
China
Production Capacity
3000/Per Years

Product Description

water saving closed loop cooling tower for Refinery plant

closed loop cooling tower advantage

we can offer cheap closed cooling tower price
♦protect process fluids from contmination
♦ Maximize system efficiency by reducing fouling and scaling tendencies
♦ Reduce system energy costs
♦ Reduce system maintenance costs
Water Saving Closed Loop Cooling Tower for Refinery Plant

 closed loop cooling tower pictures show
Water Saving Closed Loop Cooling Tower for Refinery Plant

Water Saving Closed Loop Cooling Tower for Refinery Plant

closed loop cooling tower parameters
 


MODEL

CAPACITY
(M3/h)

FAN

WATER SPRAYING PUMP

INLET/OUTLET DN(MM)

WEIGHT

DIMENSION

QTY

POWER(K/W)

AIR VOLUME PER SET(M3/h)

QTY

POWER(K/W)

WATER VOLUME PER SET(M3/h)

SHIPPING
(KG)

OPERATIONG
(KG)

LENGTH
(MM)

WIDTH
(MM)

HEIGHT
(MM)
BHX-30 30 1 3 35000 1 1.1 53 DN80 2390 3790 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 53 DN100 2510 3910 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.5 70 DN100 2760 4340 1925 2580 4220
BHX-60 60 1 5.5 75000 1 1.5 70 DN100 3290 5140 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 70 DN100 3680 5530 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 100 DN100 4230 7650 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 100 DN125 4510 7930 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 100 DN125 4620 8040 3770 2200 4965
BHX-110 110 3 3 40000 1 3 150 DN125 6170 10170 4240 2200 4720
BHX-125 125 3 4 45000 1 3 150 2-DN100 6510 10510 4240 2200 4965
BHX-135 135 4 3 45000 1 4 180 2-DN100 7100 11950 5610 2200 4220
BHX-150 150 4 3 40000 1 4 180 2-DN100 7310 12160 5610 2200 4730
BHX-165 165 4 4 45000 1 4 180 2-DN100 7590 12440 5610 2200 4965
BHX-180 183 4 4 45000 1 5.5 233 2-DN125 8920 15580 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 233 2-DN125 9330 15990 7450 2200 4720
BHX-225 226 4 4 45000 1 5.5 233 2-DN125 9550 16210 7450 2200 4965
BHX-250 250 5 4 45000 1 4 180 4-DN100 11650 19090 9300 2200 4720
BHX-265 265 5 4 45000 1 4 180 4-DN100 12350 19790 9300 2200 4965
BHX-280 280 6 4 45000 1 4 180 4-DN100 12490 19930 9300 2200 4965

MODEL

CAPACITY
(M3/h)

FAN

WATER SPRAYING PUMP

INLET/OUTLET DN(MM)

WEIGHT

DIMENSION

QTY

POWER(K/W)

AIR VOLUME PER SET(M3/h)

QTY

POWER(K/W)

WATER VOLUME PER SET(M3/h)

SHIPPING
(KG)

OPERATIONG
(KG)

LENGTH
(MM)

WIDTH
(MM)

HEIGHT
(MM)
BNX-10 12 1 1.5 18000 1 0.55 23 DN50 890 1660 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 DN50 1370 2480 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 DN50 1990 3620 1925 1840 3840
BNX-40 43 1 4 60000 1 1.1 45 DN80 2120 3790 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 DN80 2420 4490 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 DN80 2690 4760 2470 1840 4450
BNX-70 70 1 7.5 100000 1 2.2 84 DN100 3650 6080 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 DN100 4150 7480 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 DN100 4680 8010 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 DN125 5120 8450 3770 1840 4450
BNX-110 110 2 5.5 75000 1 3 120 DN125 5360 9430 3770 2200 4220
BNX-125 125 2 5.5 75000 1 3 120 2-DN100 5980 10050 3770 2200 4450
BNX-135 135 2 5.5 87000 1 4 170 2-DN100 6230 11270 4846 2200 4350
BNX-150 150 2 7.5 100000 1 4 170 2-DN100 6560 11590 4846 2200 4650
BNX-165 165 3 4 65000 1 4 170 2-DN100 7850 13730 5610 2200 4350
BNX-180 183 3 5.5 75000 1 4 170 2-DN125 8450 14330 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 4-DN80 9180 15380 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 4-DN80 9780 17340 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 4-DN100 10860 18520 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 4-DN100 11480 20880 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 4-DN100 11720 21120 9030 2200 4965


closed loop cooling tower main parts
Water Saving Closed Loop Cooling Tower for Refinery Plant



closed loop cooling tower shipping 

We packing with water cooling tower with protective film,and we load goods by 20feet/40feet high container.
Water Saving Closed Loop Cooling Tower for Refinery Plant

closed loop cooling tower application
Evaporative Condenser is widely used in energy chemical industry,Pharmaceuticals coal, electricity, industrial refrigeration, beer,beverage,-food processing, the cold storage, the building air conditionin g refrigeration,etc

Chemical medicine:Inter-cooling of methanol/methanol synthetic ammonia compressor / Syngas cooling condensation / Methanol distillation process cooling condensation / Gas cooling of natural gas or coke gas exchange process / 

Purification process as weoo as cooling condensation / Steam condensation of turbine / Ethyl acetate condensation

Water Saving Closed Loop Cooling Tower for Refinery Plant


closed loop cooling tower 
customers visiting
Water Saving Closed Loop Cooling Tower for Refinery Plant

our closed loop cooling tower foreign exhibition
Water Saving Closed Loop Cooling Tower for Refinery Plant



Company informations

1. One of the biggest cooling tower & evaporative condenser manufacturers in China
2. Annual productivity 3000sets
3. Supply OEM/ODM
4. Our products such as cooling tower, evaporative condenser, pvc fill have been exported to many countries such like America, Mexico, Malaysia, Chile, India, Dubai etc
5.Professionals:
We have 52 professionals working on product R&D area, 21 of th em have senior professional titles and 12 professionals have doctor degrees.
6.Capability:
Customize product based on different application areas, stru ctures and materials.
Analyze cooling system based on the data collected from the sample installed, and come up with the solution
Help end-users to solve the problems related to the cooling system.
7.Achievements:
12 national new product categories, 121 national patents and Pr ovincial level technology research & innovation projects.
Water Saving Closed Loop Cooling Tower for Refinery Plant


our company have evaporative condenser,closed cooling tower,pvc fill,ect any requirements,please contact us,and we will offer detailed proposal and quotation to you

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
50
Year of Establishment
2012-01-13