Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American

Product Details
Customization: Available
After-sales Service: on Site
Warranty: 2 Years
Still deciding? Get samples of US$ 3000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
  • Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Projects and Partners
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Product
Closed Combined Flow Evaporative Condenser
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/Ab B/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Advantage
Water Saving
Structure
Compact
Shape
Bottle/Square
Casing
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Fan Blade
SS304/Pag/Aluminum
Pump Brand
Cnp/East/Kaiquan
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Packaging & Delivery

Package Size
3770.00cm * 3200.00cm * 4568.00cm
Package Gross Weight
8000.000kg

Product Description

Product Description

Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American

Closed Circuit cooling tower

Combined Flow Cooling Tower
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American1-Excellent Heat Exchange Performance

Parallel air and water path as well as the combination of coils and PVC fill, this effectively avoid the dry spot and scale formation, and improve the heat exchange performance.
2-Convenient Maintenance
Huge maintenance space makes it convenient to inspect the product. Technicians can enter the cooling tower during operation time.
3-Convenient Transportation and Installation
The cooling tower is designed to be standard upper body part and bottom body part, making it is able to be shipped separately and saves
transportation and installation cost.

4-Slope Water Basin Design
Suspended PVC fill and sloped water basin floor toward the drain facilitate cleaning

Counter Flow Cooling Tower
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American1-No infill designed, more compact structure, lower profile, less installation area required,and easy for transport and installation.
2-Suitable to severe environment as its structure much more close, which couldvprevent from sand and dust. So it widely used for casting workshop,mining factory etc.
3-Suitable to high temperature fluid, because hot spraying water will not distort pvC fill as no pvC fill designed.
4-Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.

Working PrincipleWater Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American

 

 
Product Parameters

Technical Database

Combined Flow Cooling Tower
MODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BHX-30 30 1 3 135000 1 1.1 36 1925 2380 4220
BHX-40 40 1 4 45000 1 1.1 45 1925 2380 4220
BHX-50 50 1 5.5 65000 1 1.1 45 1925 2350 4220
BHX-60 60 1 5.5 75000 1 1.5 65 1925 2900 4220
BHX-70 70 1 7.5 87000 1 1.5 65 1925 2900 4965
BHX-80 80 2 4 45000 1 2.2 84 3770 2200 4220
BHX-90 90 2 4 45000 1 2.2 84 3770 2200 4720
BHX-100 100 2 4 45000 1 2.2 84 3770 2200 4965
BHX-110 110 3 3 40000 1 3 120 4240 2200 4720
BHX-125 125 3 4 45000 1 3 120 4240 2200 4965
BHX-135 135 4 3 45000 1 3 120 5610 2200 4220
BHX-150 150 4 3 40000 1 3 120 5610 2200 4730
BHX-165 165 4 4 45000 1 3 120 5610 2200 4965
BHX-183 183 4 4 5000 1 4 170 7450 2200 4220
BHX-200 200 4 4 45000 1 5.5 230 7450 2200 4730
BHX-226 226 4 4 45000 1 5.5 230 7450 2200 4965
BHX-250 250 5 4 45000 1 5.5 230 9300 2200 4720
BHX-265 265 5 4 45000 1 5.5 230 9300 2200 4965
BHX-280 280 6 4 45000 1 5.5 230 9300 2200 4965

Counter Flow Cooling Tower
ODEL CAPACITY FAN PUMP DIMENSION
QTY POWER AIR VOLUM PER SET QTY POWER WATER VOLUME PER SET L W H
BNX-10 12 1 1.5 18000 1 0.55 23 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 1925 1840 3840
BNX-40 42 1 4 60000 1 1.1 45 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 2470 1840 4450
BNX-70 70 1 7.5 10000 1 2.2 84 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 3770 1840 4220
BNX-110 110 2 5.5 75000 1 3 120 3770 2200 4450
BNX-125 125 2 5.5 75000 1 3 120 3770 2200 4350
BNX-135 135 2 5.5 87000 1 4 170 4846 2200 4650
BNX-150 150 2 7.5 100000 1 4 170 4846 2200 4350
BNX-165 165 3 4 65000 1 4 170 5610 2200 4650
BNX-180 183 3 5.5 75000 1 4 170 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 9030 2200 4965

Product Details
Combined Flow Cooling Tower
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North AmericanCounter Flow Cooling Tower
 Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North AmericanWater Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North AmericanWater Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American          
Production Process
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American

 
Company Profile

HACST is a leading global manufacturer of cooling towers, evaporative condensers and air-cooled heat exchangers.Providing full-service cooling solutions and support to customers in the heating, industrial, refrigeration and process cooling markets in China since the year of 1975.

HACST is a state level high-tech enterprise and one of the largest heat exchanger manufacturers in China, with a state-level testing laboratory and three large plants. It's the first one in the industry gets ISO9001 Quality Management System Certification and TS16949 Quality Management System Certification.


Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
Packaging & Shipping

Shipment Procedures

Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
Projects and Partners

Projects

Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
Customer Visiting and Exhibition
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North AmericanWater Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
Cooperated Partner
Water Cooler Closed Circuit Fluid Cooler Cross Cooling Tower for North American
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier