Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station

Product Details
Customization: Available
After-sales Service: on-Site Installation
Warranty: 2 Years
Still deciding? Get samples of US$ 3000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
  • Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Find Similar Products
  • Overview
  • Product Description
  • Industry Application
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
  • Projects and Partners
  • FAQ
Overview

Basic Info.

Model NO.
BHX/BNX
Ventilation Mode
Mixing Ventilation
Material
Metal
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Product
Closed Combined Flow Evaporative Condenser
Maintenance
Ladders and Access Doors Attached
Drift Rater
Less Than 0.005%
Motor Brand
Weg/Siemens
Heat Transfer Efficiency
High
Coil
Stainless Steel/Hot-DIP Al-Zn Alloy-Coated Steel
Spraying Pump
Low Head Lift, Large Flow Rate
Character
Energy Saving and Easy Maintainance
Color
Customization
Advantage
Water Saving
Structure
Compact
Motor
Siemens/Weg
Casing
Customization
Application
Data Center
Package
Customization
Transport Package
Standard Seaworthy Container
Specification
3770*1840*4450
Trademark
HACST
Origin
China
HS Code
8419500090
Production Capacity
2000sets/Year

Packaging & Delivery

Package Size
11550.00cm * 2200.00cm * 4568.00cm
Package Gross Weight
200000.000kg

Product Description

Product Description

Cooling towers are devices used to dissipate waste heat into the atmosphere. There are two main types: counter flow cooling towers and cross flow cooling towers.

 

1. Counter Flow Cooling Tower:

   - In a counter flow cooling tower, air flows vertically upwards while the water flows downwards.

   - This design allows for efficient heat exchange since the water and air move in opposite directions, maximizing the temperature difference between them.

   - The hot water enters at the top of the tower and is distributed over the fill media. As it trickles down, it exchanges heat with the upward-flowing air, cooling in the process.

   - counter flow towers typically have a smaller footprint and are more energy-efficient compared to cross flow towers.

 

2. Cross Flow Cooling Tower:

   - In a cross flow cooling tower, air flows horizontally across the downward-flowing water.

   - Water is distributed over the fill media while air is blown horizontally across the water flow.

   - Heat exchange occurs as the air passes over the water, extracting heat from it.

   - cross flow towers are simpler in design and construction compared to counter flow towers but may be less efficient in terms of heat exchange.

 

Both types have their advantages and are chosen based on factors like space availability, efficiency requirements, and operational conditions.
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station


Closed Circuit cooling tower

Combined Flow Cooling Tower
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Counter Flow Cooling Tower
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station

Working PrincipleCounter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Industry Application

Cooling towers can be used to cool a data center indirectly through a process called water-side economization. Here's how it works:

1. Heat Dissipation:
   - Heat generated by the IT equipment in the data center is transferred to a water loop through the use of heat exchangers or water-cooled systems.

2. Water Circulation:
   - The hot water from the data center's cooling system is circulated to the cooling tower.

3. Evaporative Cooling:
   - In the cooling tower, the hot water is distributed over the fill material (typically made of plastic or wood) while ambient air is blown through the tower by fans.
   - As the water flows over the fill material, it is exposed to the air, causing some of it to evaporate. This process removes heat from the water, cooling it down.

4. Heat Rejection:
   - The cooled water is then returned to the data center's cooling system, where it absorbs more heat from the IT equipment and the cycle repeats.

5. Water Treatment and Maintenance:
   - It's essential to treat the water in the cooling tower to prevent scale, corrosion, and biological growth, which can affect its efficiency and lifespan.
   - Regular maintenance, including cleaning the fill material and inspecting mechanical components, is necessary to ensure optimal performance and longevity of the cooling tower.

By utilizing a cooling tower for water-side economization, data centers can take advantage of ambient air temperature to cool the water used in their cooling systems, reducing the reliance on mechanical refrigeration and lowering energy consumption. This approach can be particularly effective in regions with favorable climate conditions, where ambient air temperatures are low enough to provide adequate cooling without the need for traditional mechanical cooling systems.

Product Parameters

Technical Database

Combined Flow Cooling Tower/Cross Flow Cooling Tower


Counter Flow Cooling Tower 
Model Capacity (m3/h) Axial Fan Water Spraying Pump Dimension (mm)
Qty  Motor Power (kw) Air Volume
Per Set (m3/h)
Qty Motor Power (kw) Water Volume
Per Set (m3/h)
L W H
BNX-10 12 1 1.5 18000 1 0.55 23 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 1925 1840 3840
BNX-40 42 1 4 60000 1 1.1 45 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 2470 1840 4450
BNX-70 70 1 7.5 10000 1 2.2 84 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 3770 1840 4220
BNX-110 110 2 5.5 75000 1 3 120 3770 2200 4450
BNX-125 125 2 5.5 75000 1 3 120 3770 2200 4350
BNX-135 135 2 5.5 87000 1 4 170 4846 2200 4650
BNX-150 150 2 7.5 100000 1 4 170 4846 2200 4350
BNX-165 165 3 4 65000 1 4 170 5610 2200 4650
BNX-180 183 3 5.5 75000 1 4 170 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 9030 2200 4965
Detailed Photos

Product Details

Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
 Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station    
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station

 

 

Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Certifications

Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Packaging & Shipping

Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Projects and Partners

 

Projects
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Customer Visiting and Exhibition
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power StationCounter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
Cooperated Partner
Counter-Flow Closed Circuit Cooling Tower with Steel and FRP for Power Station
FAQ

1 Q: Is your company a manufacture or a trading company?

   A: We are a leading cooling tower manufacturer and trading combo with more than 40 years producing experience since 1975. 
       The famous brand-"Heng An" is well known not only China but all over the world.
       As a group company loacted in Weifang Citey of China, we have more than 1000 employees, area of 34hectares and total assets of USD 160 million.


2 Q: What is the difference between a "counter flow" and a "cross flow" cooling tower?

   A: The cross flow or counter flow designation characterizes the orientation of the airflow within the heat-transer medium (fill) in the tower with respect to the direction of water flow. In counter flow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill. Hence the air and water travel in opposite directions.
        In cross flow cooling tower, the air passes through the fill medium in a horizontal direction, thus crossing the downward water flow.
        At same situation, counter flow tower are inherently more efficient than cross flow tower.


3 Q: How do you get repair parts and how long does it take?
   
   A: We have workshop and backup store supplying all parts. 90% of spare parts can be distributed to any plae on the world within one week.


4 Q: What if you don't have the professional engineers to install or maintain the tower?

    A: We could dispatch experienced engineer on site to install the towers and train your staff for tower operation and maintaince. 

5 Q: How can I choose a suitable cooling tower?

   A: If you are available to provide the following information, we can help you to choose the suitable cooling tower.

Application Which industry or system using for? For example, HAVC system, casting cooling system
Water flow capacity How many tons of water treatment per hour?
Inlet water temp. Tempreture of hot water to be cooled
Outlet water temp. Tempreture of cooled water, usually it would be at least 3-4 ºC higher than the bulb tempreture.
Wet bulb temp. Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers.
Power supply The standard is 380V/3 phases and we have stock. But for customization, the delivery time would be longer.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier